Additional functionality

9.1

Additional functionality

In addition to the standard functionality (heating and hot water production etc), a wide range of extra functionality is available as acces-

sory, or from factory, depending on the heat pump and selected application.

Explanation:

When "BM" is typed, this means that the functionality is standard and available on the BM card fitted in the heat pump from facto-

ry.

When "EM3:0" is typed, this means that the functionality is available with the expansion module EM3.

Space is available for EM3 in the electrical cabinet.

(=the function of the I/O is set in the controller in the installation menu when activating functions)

Use position numbers in table below and see electrical wiring label in the end of this manual to see available combinations on the

different heat pumps. For EM3, see EM3 manual.

Sensors used are PT1000 type. Mixing valves with 0-10V control and 24V supply.

The table below is created with the functionality available from soft ware 10.0. Additional functionality may be added later.

Note: not valid does not support all functionality as normal Calibra and vice versa. (e.g. Active cooling is not supported on Calibra Cool

with soft ware 10.01, only inbuilt passive cooling.) Buffer tank is not supported in soft ware 10.01

Functionality

Calibra Cool

Connections

Position num-

bers used

Remark

Room sensor, PT1000 type

BM

T31

132

 

Room sensor, Modbus type

BM

Mod Bus Acces-

sory

62

Room sensor genesis modbus type

Connected to MBa connection.

BMS (connection to building manage-

ment systems)

BM

BMS, MBe

173

 

External auxiliary heater

Requires EM3:0

T85, AO73, FR64,

R51

72, 108, 51, 117  

Smart Grid / EVU

BM

D21, D22

408, 409

 

Flow guard

BM

D23

71

 

Distribution circuit 1 (extra under

shunt group for heating)

Requires EM3:0

A071, T81, FR61

107, 108, 109

Possible to use as a second lower set

heat curve, heating only.

Alarm relay (Sum Alarm output)

Requires EM3:0

R2

344

 

Pool

Requires EM3:0

U94, T84, TR67,

T83

60, 101, 183,

342

See EM3 manual.

Cooling mode output signal

BM

R1

347

Relay will close when the heat pump

is in cooling mode. (= signal to ex-

ternal systems)

Cooling mode input signal

BM (separate termi-

nal)

D24

346

For external start of cooling.

Reversing valve radiator circuit

BM

TR9

310

Separate heating/cooling circuit.

External start brine pump

Requires EM3:0

-

-

See EM3 manual.

Current limiter

Requires EM3:0 or

separate accessory

-

-

See EM3/accessory manual.

* The function may not be possible to combine with all other functions, see electrical connections label for explanation.

Installation Guide

Calibra Cool

Thermia AB

BWCC01IG0102

37

Summary of Contents for Calibra Cool

Page 1: ...Installation Guide Calibra Cool BW WW models www thermia com...

Page 2: ...anty if these instructions are not adhered to during installation or service The English language is used for the original instructions Other languages are a translation of the original instructions D...

Page 3: ...power supply 20 6 2 Outdoor sensor 20 6 3 Power supply 400V 21 6 4 External reversing valve Optional 21 6 5 Fuse sizes 400V 22 7 Filling and bleeding 23 7 1 Filling and bleeding the brine circuit 23...

Page 4: ...cessories functions etc 38 10 Electrical connections 39 10 1 Calibra Cool electrical connections 400V this label is also fitted on the electrical cabinet of the heat pump 39 Installation Guide Calibra...

Page 5: ...sk of personal injury Indicates a possible danger that can lead to fatal or serious injury if necessary measures are not taken Caution Risk of installation damage Indicates a possible hazard that can...

Page 6: ...conditions with regards to hard water a softening filter may be necessary to use install The softening filter softens the water cleans any impurities and prevents the buildup of calcification The hot...

Page 7: ...e is used for the collector circuit vertical horizontal In most applications a T 3 5 K is desired for most efficient running The lengths of the collectors are based on ethanol 30 at 0 C PEM40 Calibra...

Page 8: ...show ing BW model WW model does not include filling device and level vessel for cold carrier 3a 1 Alternative 1 heating and cooling distributed to the same system not recommended to normal convection...

Page 9: ...ng Cooling system supply pipe 28 mm 4 Heating Cooling system return pipe 28 mm 5 Connection for bleed valve 28 mm 6 Hot water line 22 mm 7 Cold water line 22 mm 8 Lead in for supply sensor and communi...

Page 10: ...pressure not included in delivery Outdoor sensor Filter ball heating system Cable inlets Document holder Grommets 28 Tube insulation Plastic cap Filling device brine WW version Filter ball Level vess...

Page 11: ...space requirement and Recommended location 3 1 Transportation The heat pump must not be transported lying down Max 45 Maximum tilt 45 Calibra Cool 157 169 kg Installation Guide Calibra Cool Thermia AB...

Page 12: ...r near a bedroom The surrounding walls can amplify the sound from the heat pump 1930 mm 5 C OK 30 C 300 mm 300 mm 300 mm 10 mm 600 mm x4 1 2 3 Adjust the heat pump using the adjustable feet so that it...

Page 13: ...mplify the removal The heat pump should be placed on a stable floor with a floor well so any condensation may drain from the condensation hole in the bottom of the heat pump preferably a concrete floo...

Page 14: ...l 86 Safety valve Max 3 bar heat pump recommended 1 5 bar 87 Safety valve 9 bar hot water 91 Dirt strainer with shut off valve DN 25 113 Expansion vessel Make sure that a free flow is always possible...

Page 15: ...nt or the thermic expansion of the brine is expected to exceed the volume of the vessel it should be considered to install a pressure ves sel instead Picture showing a common layout for BW model of fi...

Page 16: ...ure it reaches the 32 mm mark To disassemble if required 1 Push the plastic ring inwards 2 Pull the pieces apart 1 2 Insulate the brine pipe and prepare with the insulation tape before installing the...

Page 17: ...pipes 3 Install the insulated pipes from the inside of the heat pump and out Pay attention to which one of the pipes are brine in and brine out see picture below 4 Press the pipes on to the connection...

Page 18: ...e pipes on to the connections in the heat pump see picture below Install the insulated pipes from the inside of the heat pump and out Pay attention to which one of the pipes are brine in and brine out...

Page 19: ...ipes 3 Press the pipes on to the connections in the heat pump see picture below Install the insulated pipes from the inside of the heat pump and out Pay attention to which one of the pipes are brine i...

Page 20: ...must be disconnected before electrical installation can commence 400V version Calibra Cool complies with IEC 61000 3 12 without conditional connection 6 2 Outdoor sensor 50 m 0 75 mm2 50 120 m 1 5 mm...

Page 21: ...xternal reversing valve Optional In systems with separated cooling circuit a reversing valve can be fitted outside the heat pump For connection on to the heat pump see chapter Electrical connections t...

Page 22: ...rent of compressor 12 A at 230V nominal The picture below shows the actual current consumption with the recommended fuse size shown in brackets 400V 3N 50 Hz fuse C curve Calibra Cool I max Fuse 13A 1...

Page 23: ...1 Fill the water heater with cold water by opening the shut off valve on the incoming cold water pipe Open one of the hot water taps in the house 2 Then fill the water heater coil and the heating sys...

Page 24: ...ut off valve 94 Filling device 100 Safety valve 121 Brine in 122 Brine out A Shut off valve part of 94 B Shut off valve part of 94 C Dirt strainer with shut off valve part of 94 D External container E...

Page 25: ...art screen 2 Press 3 Press on the text Language 4 Select language 5 Press to return to System settings Or press in the upper left corner to return to the Menu screen 8 1 2 Setting date and time 1 Pres...

Page 26: ...he Curve indicator symbol 11 20 20 17 10 5 0 5 15 25 40 80 60 21 29 34 40 44 1 51 59 Auto supply line C outdoor C 1 Press on the Start screen to open the Menu screen 2 Press 3 Press if the Heat curve...

Page 27: ...creen to open Menu screen 2 Press 3 Press to show the heat curve graph 4 Press to show other heating settings The heat curve is the base for all space heating adjustments The curve number example 40 c...

Page 28: ...ith 1 C step Note Fixed supply line set point that may be available in the menu is not used in normal installations and should normally not be activated The heat curve shows the desired supply line te...

Page 29: ...hows that the heat curve window is active This window is the default window Shows that the heating settings window is inactive Press on the symbol to open heating set tings Shows that the heating sett...

Page 30: ...ay apply if external devices are installed and activated After completion of the test close manual test Parameter Meaning Circulation pump 0 stop circulation pump 1 start circulation pump Brine pump o...

Page 31: ...trical power to the heat pump when the compressor is running When planned set the operating mode to off position and allow compressor to stop completely before shutting off the electrical power to the...

Page 32: ...tart screen to open the Menu screen 2 Press on Settings 3 Press on the text Heat pump 4 Navigate to Brine in monitoring 5 Set desired minimum temperature 6 Press to activate 7 Confirm settings by pres...

Page 33: ...two criteria shall be met Cooling season Indoor temperature exceeds the desired indoor temperature for heating temperature on start page the set value for Passive cooling room sensor offset default 2...

Page 34: ...eat pump 8 8 Selecting hot water settings Hot water settings The hot water production is activated from factory but the setting the customers hot water mode can be selected during commission ing 1 Go...

Page 35: ...on equipment switched on Activation deactivation of push pull control or switch functions equipment on off Press on the symbol to change mode The symbol indicates deactivated function equipment switch...

Page 36: ...heat pump is in space heating mode Restriction timer Visible in the top of the display when the heat pump is in restriction to start Tap water mode Visible in the top of the display when the heat pum...

Page 37: ...h soft ware 10 01 only inbuilt passive cooling Buffer tank is not supported in soft ware 10 01 Functionality Calibra Cool Connections Position num bers used Remark Room sensor PT1000 type BM T31 132 R...

Page 38: ...ou enable a function you enable the different functions in a similar way 1 Login 607080 2 Go to SETTINGS INSTALLATION and select desired function Activate by selecting BM if function is connected to B...

Page 39: ...t exchanger Hot Water Supply line Borehole return line Return line Heat pump refrigerant circuit BW models BW models WW models Space heating or cooling Cooling mode Cooling mode Heating mode Heating m...

Page 40: ...Installation Guide Calibra Cool BWCC01IG0102 Thermia AB 40...

Page 41: ...Installation Guide Calibra Cool Thermia AB BWCC01IG0102 41...

Page 42: ...Installation Guide Calibra Cool BWCC01IG0102 Thermia AB 42...

Page 43: ...Installation Guide Calibra Cool Thermia AB BWCC01IG0102 43...

Page 44: ...rial Thermia reserves the right to alter its products without notice This also applies to products already on order provided that such alterations can be made without subsequential changes being neces...

Reviews: