8.1.4
Floor heating or radiator system
Important: If the system shall be configured to Floor heating or similar, it is a must to set the heat pumps default value to floor heating. If
this is not done, the "factory reset" button will reset the heat curve and max/min supply line temperatures to default values for radiator
systems, which may cause damages on systems with e.g. floor heating.
If your house has floor heating, the supply line temperature must not exceed the values recommended by the floor manufacturer. Oth-
erwise the floor might get damaged.
To change default heat settings from Radiator to Floor heating (or reverse):
1. Press
on the Start screen to open the Menu screen.
2. Press
3. Press
if the Heating settings window is not shown.
4. Chose heating type for underfloor heating systems or radiator systems
5. Make the desired changes.
6. Confirm settings by pressing
8.1.5
Adjusting the Heat Curve
The Curve indicator has two modes that can be toggled by pressing the Curve indicator symbol.
11:20
20
17
10
5
0
-5
-15
-25
40
80
60
21
29
34
40
44
+1
51
59
Auto
supply line (˚C)
outdoor (˚C)
1. Press
on the Start screen to open the Menu screen.
2. Press
3. Press
if the Heat curve is not shown.
4. There are two ways of adjusting the heat curve:
▪
If the Curve indicator
40
is lit, press or to adjust the entire curve.
Or:
▪
If the Curve indicator
40
is not lit individual points can be moved sepa-
rately by pressing the desired individual point and pressing and
to the desired temperature.
5. Confirm the new selection by pressing
The heat curve indicator value shows the temperature of the water supplied to the heating system ("supply line temperature") at an
outdoor temperature of 0 °C.
8.1.6
Heating Settings
In Heating settings, you can set seasonal stop, min/max supply line temperature and comfort factor.
(The
Comfort factor
(0 - 3) determines how much influence 1 step +/- on the comfort wheel will have on the desired Supply line (HP)
value. If the Comfort factor is set to for example 3, an increase of the Comfort wheel setting with +1 will result in an increase of the
supply line temperature with +3 ºC.)
Installation Guide
Calibra Cool
BWCC01IG0102
Thermia AB
26
Summary of Contents for Calibra Cool
Page 1: ...Installation Guide Calibra Cool BW WW models www thermia com...
Page 40: ...Installation Guide Calibra Cool BWCC01IG0102 Thermia AB 40...
Page 41: ...Installation Guide Calibra Cool Thermia AB BWCC01IG0102 41...
Page 42: ...Installation Guide Calibra Cool BWCC01IG0102 Thermia AB 42...
Page 43: ...Installation Guide Calibra Cool Thermia AB BWCC01IG0102 43...