Themis Computer
RES-32XR3-S for X8DTL-6/6F Installation Manual
3.3.3.7 Patrol Scrubbing
A memory error-correction scheme that works in the background looking for and
correcting resident errors. The options are Enabled and
Disabled
.
3.3.3.8 Channel Interleave/Bank Interleave
This item allows the user to set memory interleave schemes for onboard memory
channels or banks. The options for Channel Interleaving are 1 Way, 2 Way, 3 Way, 4
Way, and
6 Way.
The options for Bank Interleaving are 1 Way, 2 Way, 3 Way,
4
Way.
3.3.3.9 Throttling - Closed Loop / Throttling - Open Loop
Throttling improves reliability and reduces power in the processor by automatic
voltage control during processor idle states. Available options are
Disabled
and
Enabled. If Enabled, the following items will appear:
Hysteresis Temperature (Closed Loop only)
Temperature Hysteresis is the temperature lag (in degrees Celsius) after the set
DIMM temperature threshold is reached before Closed Loop Throttling begins. The
options are
Disabled
, 1.5°C, 3.0°C, and 6.0°C.
Guardband Temperature (Closed Loop only)
This is the temperature which applies to the DIMM temperature threshold. Each step
is in 0.5°C increment. The default is
[006]
. Press “+” or “-” on your keyboard to
change this value.
Inlet Temperature (Closed Loop/Open Loop)
This is the temperature detected at the chassis inlet. Each step is in 0.5°C increment.
The default is
[070]
. Press “+” or “-” on your keyboard to change this value.
Temperature Rise (Closed Loop/Open Loop)
This is the temperature rise to the DIMM thermal zone. Each step is in 0.5°C incre-
ment. The default is
[020]
. Press “+” or “-” on your keyboard to change this value.