1-16
Themis Computer
RES-32XR3-S for X8DTL-6/6F Installation Manual
1.9.2
Electrical
Table 1-6
lists the electrical specifications for the RES-32XR3-S.
1.9.2.1 System Power
The RES-32XR3-S operates with two N+1 redundant AC power supplies of 750-
watts capacity each that auto-range single-phase AC input from 100 to 240 VAC (47
to 63 Hertz) sources. Filtered and fused (internal) AC is supplied to each power sup-
ply from a rear-mounted power connection.
Two
optional
N+1 redundant DC power supplies of 750 watts (48 volts) or 500 watts
(28 volts) each may be substituted for the AC power supplies (see
Table 1-6
). These
supplies should be specified at the time of your order.
Table 1-6.
RES-32XR3-S Electrical Specifications
Parameter
Description
AC (120 volts, 750W)
DC (48 volts, 750W)
DC (28 volts, 500W)
Input Power (
typical
)
z
420 watts (
typical
)
a
z
420 watts (
typical
)
a
z
450 watts (
typical
)
a
Input Current
z
3.5 amperes @120 Vac
z
13.5 amperes @48 Vdc
z
16 amperes @28 Vdc
Input Frequency
z
47–63 Hertz
NA
b
NA
b
Input Voltage
z
100–265 Vac,
internally fused
z
40–72 Vdc,
internally fused
z
18–36 Vdc,
internally fused
Input VA Rating
z
425 VA
NA
NA
BTU Rating
z
1447 BTU/hour
z
1447 BTU/hour
z
1447 BTU/hour
Power Factor
z
0.99
NA
NA
Input Leakage Current
z
3.5 mA
NA
NA
Plug Type
z
IEC
z
Y-Type
(SVS5-4 or equivalent)
z
Y-Type
(SVS5-4 or equivalent)
a—Does not include plug-in PCI cards.
b—