5.9.3
SAR requirements specific to portable mobiles
Mobile phones, PDAs or other portable transmitters and receivers incorporating a GSM module
must be in accordance with the guidelines for human exposure to radio frequency energy. This
requires the Specific Absorption Rate (SAR) of portable 5G M.2 Data Card MV31-W based ap-
plications to be evaluated and approved for compliance with national and/or international reg-
ulations.
Since the SAR value varies significantly with the individual product design manufacturers are
advised to submit their product for approval if designed for portable use. For European and US
markets the relevant directives are mentioned below. The manufacturer of the end device is in
the responsibility to provide clear installation and operating instructions for the user, including
the minimum separation distance required to maintain compliance with SAR and/or RF field
strength limits, as well as any special usage conditions required to do so, such as a required
accessory, the proper orientation of the device, the max antenna gain for detachable antennas,
or other relevant criteria. It is the responsibility of the manufacturer of the final product to verify
whether or not further standards, recommendations or directives are in force outside these ar-
eas.
Products intended for sale on US markets
IEEE C95.1
Considerations for evaluation of human exposure to Electromagnetic
Fields (EMFs) from Mobile Telecommunication Equipment (MTE) in the
frequency range 30MHz - 6GHz
Products intended for sale on European markets
EN 50360
Product standard to demonstrate the compliance of mobile phones with
the basic restrictions related to human exposure to electromagnetic
fields (300MHz - 3GHz)
EN 62311:2020
Assessment of electronic and electrical equipment related to human
expo-sure restrictions for electromagnetic fields (0 Hz - 300 GHz)
Please note that SAR requirements are specific only for portable devices and not for mobile
devices as defined below:
•
Portable device:
A portable device is defined as a transmitting device designed to be used so that the radi-
ating structure(s) of the device is/are within 20 centimeters of the body of the user.
•
Mobile device:
A mobile device is defined as a transmitting device designed to be used in other than fixed
locations and to generally be used in such a way that a separation distance of at least 20
centimeters is normally maintained between the transmitter's radiating structure(s) and the
body of the user or nearby persons. In this context, the term ''fixed location'' means that the
device is physically secured at one location and is not able to be easily moved to another