Cinterion
®
MV31-W Hardware Interface Description
5.6 Electrostatic Discharge
75
t
MV31-W_HID_v01.009a
2022-04-27
Public / Preliminary
Page 62 of 76
5.6
Electrostatic Discharge
The 5G M.2 Data Card MV31-W is not protected against Electrostatic Discharge (ESD) in gen-
eral. Consequently, it is subject to ESD handling precautions that typically apply to ESD sensi-
tive components. Proper ESD handling and packaging procedures must be applied throughout
the processing, handling and operation of any application that incorporates a 5G M.2 Data Card
MV31-W module.
The 5G M.2 Data Card’s MV31-W module has been tested according to the following standards.
Electrostatic values can be gathered from the following table.
Note: The values may vary with the individual application design. For example, it matters
whether or not the application platform is grounded over external devices like a computer or
other equipment.
Table 26:
Electrostatic values
Specification/Requirements
Contact discharge
Air discharge
ETSI EN 301 489-1/7
Application connector signals
Antenna interface
4kV
8kV