Mistblowers Notice of Instructions
Page
43
of
43
FAILURE
PROBABLE CAUSE
POSSIBLE SOLUTION
Pressure increase
Obstructed
pressure
filters
Clean the filters
Foam Creation
Air in the circuit
Check o’rings, joints, hoses and suction fittings
Excessive stirring
Reduce revolutions in the PTO or circuit pressure
Check the tension of the safety valve and of the self-
cleaning filter.
Make sure that there is return to tank.
Use additive against-foaming action
Loss of Liquid of the Pump
Damaged diaphragms
Replace
Damaged piston
Replace
The distributor does not
work
Interrupted Connection
Check potential cable rupture
Check that the wires are well-connected
The valves do not close
correctly
Check possible obstructions in the valves
Check the endings of paths
There is not electrical
current
Wrong polarity. Brown is pos. (+), Blue is neg. (-).
Chec the electrical plate
Check that the fuse makes good contact with your electrical
support.