6.5.6.4.2.
Hand-operated Mode
With this mode, sectors will be able to be opened or closed when required without any sort of delay.
1.
Set the control in hand-operated working mode (tap B, N y G, if this is convenient, turning off thus the green
leds).
2.
To open or close the sectors tap the START/STOP buttons (tap D, I and E, OPEN = TURNED OFF RED LED, CLOSED =
TURNED ON RED LED).
6.6.
Air kit
Select the short or long gear of the gear box through the lever adapted for this purpose depending on the air flow with
which you want to work (see boards of performances of air units).
If the gear is not changed you will have to turn ¼ the entry of the gear box.
6.6.1.
Deflectors (air deflectors)
Depending on the model of air unit several deflectors will be able to be mounted whether with mechanical adjustment or
hydraulic adjustment, check with Teyme for the possibility of attaching them to your air unit. They have the function of
redirecting the air flow to optimize the work depending on the crop to be treated and its dimensions.
6.6.1.1.
Hand-operated Deflectors
All the hand-operated deflectors will be adjusted loosening the fixation screws, placing the deflector in the wanted
position and tightening again the screws and bolts.
6.6.1.2.
Hydraulic Deflectors Models
These deflectors are adjusted through hydraulic movements from the tractor’s cab.
•
DANGER! These moves can eventually cause injures if you are not careful. Keep people away from the range of
the air unit, whenever these moves are going to be triggered.
7.
Maintenance
7.1.
General Information
Keep all the lubricants clean and stored in a fresh and dry place to avoid pollution by dirt or condensated water. Keep
clean the oil cans, funnels and grease pistols before storing them and the points of lubrication once they have been
greased. Avoid contact for prolonged periods of time of the oil products with the skin.
Follow always the advice about recommended amounts. If the recommended amount is not shown, place grease until this
is made visible. The pictogrammes about lubrication refer to the working hours before the next lubrication.
•
DANGER! If the mistblower is cleaned with a pressure water gun, lubrication on all the machine is recommended