Mistblowers Notice of Instructions
Page
42
of
43
Replace the gear box oil. Check the gear box holder and tighten again the attachment screws.
7.10.4.
Every 100 working hours.
Make a full revision of all elements previously described.
8.
Failures Detection
8.1.
General Information
On practically all the failures, the same factors use to have some influence:
1.
Small pores or air intakes in suction will reduce the capacity of the pump or will completely stop the suction.
2.
An obstructed suction filter causes the pump not to suck correctly.
3.
The obstructed pressure filters will make the pressure increase in the manometer but descend in the nozzles’
exit.
4.
External objects in the valves can cause that the valve does not close completely. This will reduce the efficacy of
the pump.
5.
Bad assembly of the pump, specially the cases of the diaphragms, will cause air suction and therefore reduction
or poor suction of the pump.
For this reason, check ALWAYS that:
1.
The filters of section, pressure and nozzles ones are clean.
2.
The hoses have not leakages or pores, particularly those of suction.
3.
Joints and o’rings are in good condition.
4.
The manometer marks perfectly. The correct dosage depends on it.
5.
The distributor works correctly. Use clean water to test it.
8.2.
Liquid Circuit
FAILURE
PROBABLE CAUSE
POSSIBLE SOLUTION
When
activating
the
system
there
is
no
spraying
Air in the suction
Check the o’ring of the suction filter. Check the suction
pipe and hose fittings.
Check the assembly of the lids of the head of the pump
and the diaphragms.
Air in the system
Prepare the pump filling in the hose with water.
Suction/pression filters
are obstructed.
Clean the filters
Check the suction fitting and make sure that the mouth of
this is not too close from the tank’s bottom.
Loss of pressure
Incorrect Assembly
The spring of the safety valve is damaged
The suction fitting is obstructed
The suction filter is obstructed
Clogged or worn out
pump valves
Check obstructions and wear
Defective manometer
Check if there is dirt in the entry
Pressure leaps
Clogged filters
Clean the filters. Clean with clean water. If you use
powder, make sure that the stirring is activated.
Worn-out nozzles
Check that the flow of the nozzles do not exceed the 10%
Clogged tank’s air vent
Check the air vent
Air Suction
Reduce revolutions in the PTO or pressure of the circuit