7.8.
Winter Storage
Before storing your machine for the winter pause, it is advisable to give it a special care:
•
Make sure that the tank is empty and free of wastes.
•
Replace the joints and the possible losses.
•
In areas where the temperature is prone to descending below 0°C, fill the tank with 13,21 gallons of water mixed
with antifreeze and set the pump on working with the jets closed, until being sure that the pump and all the
circuit is full of antifreeze.
•
Leave the tank with the charging hole uncovered to avoid possible accumulation of gases.
•
After a full cleaning of the machine, check the paint of the frame; repair the rusted places, as the phytosanitary
products accelerate corrosion in damaged areas.
•
Start a general greasing process and change the oil in the pump and in the gear box.
•
Disassemble the manometer of pressure and keep it away of frosts and in vertical position.
•
Keep the machine in a safe, aired and closed place.
•
Make sure that the pressure regulation valve is in “zero” position.
•
Check that all protections of the machine are in perfect condition.
•
All the electrical connectors should be kept in plastic bags to protect them from humidity, dirt and corrosion.
•
Disassemble the control box if the tractor has one and keep it in a dry and clean place.
7.9.
Preparation of the machine to use it after its storage
After the storage period, the machine should be arranged to start the job of the new season with guarantees. For a correct
start, follow the next steps:
•
Assemble again the manometer of pressure. Replace the old teflon.
•
Connect the machine to the tractor including electrical wires and hydraulic adapters.
•
Check the brake.
•
Empty the tank until no waste of freeze remains.
•
Rinse completely the liquid circuit with clean water.
•
Fill in the tank with clean water and check all fonctions.
7.10.
Periods of Maintenance
7.10.1.
Every 10 working hours.
Fill in the tank with clean water, activate all fonctions and check potential losses using a bigger pressure than the usual
one.
Check visually the cone of the nozzles to detect potential imperfections.
Clean the suction and pressure filters.
Control of oil level and condition in the water pump.
7.10.2.
Every 50 working hours.
Revise the condition of the PTO shaft protection. Replace damaged parts if there are any. Tighten again the screws of the
areas which carry out bigger efforts or twisting.
Make sure that the pressure of the air tank of the pump are correct. Check the PTO shaft.
Check the fixation of the water pump.
7.10.3.
Every 250 working hours.
Check all hoses of the circuit.