6
2.10.
MECHANICAL
1.Cooling
--
Forced air cooling by internal fans.
2.Weight
kg
Less than 4.5kg.
3. Dimensions(WxHxD)
mm
W: 214.0, H: 43.6(57.0 Benchtop Version), D: 437.5(Refer to Outline drawing).
4.Vibration
--
MIL-810E, method 514.4, test condition 1-3.3.1
5.Shock
--
Less than 20G, half sine, 11mS. Unit is unpacked.
2.11.
SAFETY/EMC
EN60950.
Vout=60V: Output is SELV, IEEE/Isolated analog are SELV.
60<Vout=400V: Output is hazardous, IEEE/Isolated analog are SELV.
400<Vout=600V: Output is hazardous, IEEE/Isolated analog are not SELV.
1.Applicable standards: Safety
EMC
--
EN55024
2.Withstand voltage
--
Vout=60V models: Input-Outputs(SELV): 3.0KVrms 1min, Input-Ground: 2.0KVrms 1min,
60<Vout=600V models: Input-Haz. Output: 2.5KVrms 1min, Input-SELV: 3KVrms 1min,
Hazardous Output-SELV: 1.9KVrms 1min, Hazardous Output-Ground: 1.9KVrms 1min,
Input-Ground: 2.0KVrms 1min.
3.Insulation resistance
--
More than 100Mohm at 25℃, 70%RH.
4.Conducted emission
--
Conforms to EN55022B, FCC part 15-B, VCCI-B
5.Radiated emission
--
Conforms to EN55022B, FCC part 15-A, VCCI-A
NOTES:
*1: Minimum voltage is guaranteed to maximum 0.2% of the rated output voltage.
*2: Minimum current is guaranteed to maximum 0.4% of the rated output current.
*3: For cases where conformance to various safety standards (UL, IEC etc.) is required, to be
described as 100-240V AC (50/60Hz).
*4: At 100/200V AC input voltage and maximum output power.
*5: From 85-132V AC or 170-265V AC, constant load.
*6: From No-load to Full-load, constant input voltage. Measured at the sensing point in Remote
Sense.
*7: For load voltage change, equal to the unit voltage rating, constant input voltage.
*8: For 6V models the ripple is measured at 2-6V output voltage and full output current. For other
models, the ripple is measured at 10-100% output voltage and full output current.
*9: From 10% to 90% of rated output voltage, With rated resistive load.
*10: From 90% to 10% of rated output voltage, with rated resistive load.
*11: From 90% to 10% of rated output voltage.
2.12.
SUPPLEMENTAL CHARACTERISTICS
The supplemental characteristics data is held in each TEXIO sales and service facility. For further
details please contact the TEXIO agent nearest you.