28
Table 4-4: J1 connector terminals and functions
J1
contact
Signal
name
Function
Reference
J1-1
ENA_IN
Enable/Disable the power supply output by
dry-contact (short/open).
Sec.5-8
J1-2
J1-3
IF_COM
Isolated Interface Common. Return for the SO control,
PS_OK signal and for the optional IEEE interface.
Sec.5-7,5-10
J1-4
~7
N/C
No Connection
J1-8
LOCAL/
REMOTE
Input for selecting between Local or Remote analog
programming of output voltage and output current.
Sec.6-2
J1-9
VPGM
Input for remote analog voltage/resistance
programming of the Output Voltage.
Sec.6-1 ~
6-4
J1-10
IPGM
Input for remote analog voltage/resistance
programming of the Output Current.
Sec.6-1 ~
6-4
J1-11
VMON
Output for monitoring the power supply Output
Voltage.
Sec.6-6
J1-12
COM
Control Common. Return for VMON, IMON, CV/CC,
RMT/LCL. Connected internally to the negative sense
potential (-S).
J1-13
CV/CC
Output for Constant-Voltage/Constant-Current mode
indication.
Sec.5-9
J1-14
ENA_OUT
Enable/Disable the power supply output by
dry-contact (short/open) with ENA_IN.
Sec.5-8
J1-15
SO
Input for Shut-Off control of the power supply output. Sec.5-7
J1-16
PS_OK
Output for indication of the power supply status.
Sec.5-10
J1-17
~20
N/C
No Connection
J1-21
LOC/REM
SIGNAL
Output for indicating if the unit is in Local or Remote
analog programming mode.
Sec.6-3
J-22
VPGM_RTN
Return for VPGM input. Connected internally to the
“-S”.
Sec.6-1,6-4
6-5
J1-23
IPGN_RTN
Return for IPGM input. Connected internally to the
“-S”.
Sec.6-1,6-4
6-5
J1-24
IMON
Output for monitoring the power supply Output
Current.
Sec.6-6
J1-25
P
Output for current balance in parallel operation.
Summary of Contents for PU100-7.5
Page 2: ......
Page 10: ......
Page 17: ...7...
Page 74: ...1850 1 Tsuruma Machida shi Tokyo 194 0004 Japan http www texio jp...