4
2.
SPECIFICATIONS
2.1.
OUTPUT RATING
MODEL
6-100
8-90 12.5-60 20-38
30-25
40-19
60-12.5
80-9.5
100-7.
5
150-5 300-2.5 600-1.3
1.Rated output voltage (*1)
V
6
8
12.5
20
30
40
60
80
100
150
300
600
2.Rated output current (*2)
A
100
90
60
38
25
19
12.5
9.5
7.5
5
2.5
1.3
3.Rated output power
W
600
720
750
760
750
760
750
760
750
750
750
780
2.2.
INPUT CHARACTERISTICS
V
6
8
12.5
20
30
40
60
80
100
150
300
600
1.Input voltage/freq. (*3)
-
85~265V AC continuous, 47~63Hz, single phase.
2.Input current
(at 100/200V AC)
A
10.5/5
3.Power Factor
-
0.99@100/200V
AC、rated output power.
4.Efficiency (*4)
%
76/78
77/80
81/84
82/85
82/85
83/87
83/87
83/87
83/87
83/87
83/87
83/87
5.Inrush current at 100/200V
A
Less than 25A.
2.3.
CONSTANT VOLTAGE MODE
V
6
8
12.5
20
30
40
60
80
100
150
300
600
1.Max. Line regulation (*5)
-
0.01% of rated output voltage +2mV
2.Max Load regulation (*6)
-
0.01% of rated output voltage +2mV
3.Ripple and noise(p-p,20MHz)
(Following 30 minutes
warm-up).
mV
60
60
60
60
60
60
60
80
80
100
150
300
4.Ripple r.m.s., 5Hz~1MHz
(Following 30 minutes
warm-up.)
mV
8
8
8
8
8
8
8
8
8
10
25
60
5.Temperature coefficient
ppm/℃ 100ppm/℃ from rated output voltage, following 30 minutes warm-up.
6.Temperature drift
-
0.05% of rated Vout over 8hours interval following 30 minutes warm-up. Constant line, load & temp.
7.Rem.sense compensation/wire
V
1
1
1
1
1.5
2
3
4
5
5
5
5
8.Up-prog. response time,
0~Vomax (*9)
mS
90
120
150
250
9.Down-prog .response time:
Full load (*10)
mS
10
50
80
150
250
No load (*11)
mS
500
600
700
900
1000
1100
1200
1400
1700
2400
3000
4800
10.Transient response time
mS
Time for the output voltage to recover within 0.5% of its rated output for a load change 10~90% of rated
output current.
Output set-point: 10~100%.
Less than 1mS, for models up to and including 100V. 2mS, for models above 100V.
11.Hold-up time
mS
More than 20mS, 100V AC, rated output power.
2.4.
CONSTANT CURRENT MODE
V
6
8
12.5
20
30
40
60
80
100
150
300
600
1.Max. Line regulation (*5)
-
0.01% of rated output current +2mA
2.Max. Load regulation (*7)
-
0.02% of rated output current +5mA
3.Ripple r.m.s. 5Hz~1MHz(*8)
mA
200
180
120
76
63
48
38
29
23
18
13
8
4.Temperature coefficient
ppm/℃ 100ppm/℃ from rated output current, following 30 minutes warm-up.
5.Temperature drift
-
0.05% of rated Iout over 8hours interval following 30 minutes warm-up. Constant line, load & temp.
2.5.
ANALOG PROGRAMMING AND MONITORING
1. Vout voltage programming
---
0~100%, 0~5V/0~10V, user select. Accuracy and linearity: +/-0.5% of rated Vout.
2. Iout voltage programming
---
0~100%, 0~5V/0~10V, user select. Accuracy and linearity: +/-1% of rated Iout.