24
Table 4-1: Front Panel controls and indicators
Number
Control/Indicator
Description
Section
15
V/I CHK indicator
Green LED, lights when V/I CHK button is pressed.
16
FINE button
Voltage and Current Fine/Coarse adjustment
control. Operates as a toggie switch. In Fine mode,
the VOLTAGE and CURRENT encoders operate
with high resolution and in Coarse mode with lower
resolution (approx. 6 turns).
17
FINE indicator
Green LED, lights when the unit is in Fine mode.
18
ALARM indicator
Red LED, blinks in case of fault detection. OVP,
OTP Foldback, Enable and AC fail detection will
cause the ALARM LED to blink.
19
AC power switch
AC On/Off control.
4.3.
REAR PANEL
See Fig.4-2 to review the connections and controls located on the power supply rear panel.
Refer to Table 4-2 for explanations about the rear panel connections and controls.
Fig.4-2: Rear panel connections and controls
Table 4-2: Rear panel connections and controls
Number
Item
Description
Section
1
AC input
connector
IEC connector
3.7.1
2
DC output
Bus-bars for 6V to 60V models.
Wire clamp connector for 80V to 600V models.
3.9.6
3
Remote-In
connector
RJ-45 type connector, use for connecting power supplies to
RS232 or RS485 port of computer for remote control purposes.
When using several power supplies in a power system, the first
unit Remote-In is connected to the computer and the remaining
units are chained, Remote-In to Remote-Out.
7.3
7.4
Summary of Contents for PU100-7.5
Page 2: ......
Page 10: ......
Page 17: ...7...
Page 74: ...1850 1 Tsuruma Machida shi Tokyo 194 0004 Japan http www texio jp...