Test Results
71
JAJU324B – March 2015 – Revised July 2017
翻訳版
—
最新の英語版資料
http://www-s.ti.com/sc/techlit/TIDU832
Copyright © 2015–2017, Texas Instruments Incorporated
EMI/EMC
規格準拠、産業用温度範囲のデュアルポート・ギガビット・イーサネットの
リファレンス・デザイン
5.4.4
IEC-61000-4-4 EFT Test Results
shows the EFT test setup. During the EFT test, both Gigabit Ethernet ports where connected with a
3-m CAT7 cable to far end laptops. The capacitive clamp can be seen in the foreground of
図
図
64. IEC61000-4-4 EFT Test Setup for TIDA-00204
During the EFT tests, a UDP packet transfer was launched on each Gigabit Ethernet port. Each test level
and Gigabit Ethernet port was tested with two different PC software programs running on a laptop for
analysis, as described earlier. The test results are shown in
.
(1)
See
for test setup description.
(2)
See
for performance descriptions.
表
表
33. IEC-61000-4-4 EFT Test Results for TIDA-00204
PHENOMENON
BASIC STANDARD
LEVEL
TIDA-00204
CONNECTOR
UNDER TEST
PERFORMANCE
CRITERION
(1) (2)
COMMENT
EFT
IEC61000-4-4
±2-kV/5-kHz,
cap clamp
RJ45 port 1
B
EFT
IEC61000-4-4
±2-kV/5-kHz,
cap clamp
RJ45 port 2
B
EFT
IEC61000-4-4
±4-kV/5-kHz,
cap clamp
RJ45 port 1
B
Not required per
IEC61800-3
EFT
IEC61000-4-4
±4-kV/5-kHz,
cap clamp
RJ45 port 2
B
Not required per
IEC61800-3
To verify the number of packets lost the program during the EFT tests, a UDP packet transfer was
launched on each Gigabit Ethernet port. Each EFT voltage test level and gigabit Ethernet port was tested
with two different software programs running on the laptop for analysis of throughput and packet errors
during an EFT event.