Test Results
62
JAJU324B – March 2015 – Revised July 2017
翻訳版
—
最新の英語版資料
http://www-s.ti.com/sc/techlit/TIDU832
Copyright © 2015–2017, Texas Instruments Incorporated
EMI/EMC
規格準拠、産業用温度範囲のデュアルポート・ギガビット・イーサネットの
リファレンス・デザイン
5.4
EMC/EMI Test Results
The TIDA-00204 TI design has been tested for EMI according to CISPR 11 / EN55011 Class A radiated
emissions. For EMC immunity, the design has been tested according to IEC61800-3 and IEC61000-6-2 for
ESD, EFT, and Surge with reference to standards IEC61000-4-2, IEC61000-4-4, and IEC61000-4-5,
respectively.
The design is compliant to these standards and exceeds the voltage requirements according to
IEC61800-3 EMC immunity requirements. A summary is shown in the following tables and more details in
the following sections.
表
表
26. CISPR 11 / EN55011 Class A Radiated Emission Requirements for Category 2 and Measured
Level
REQUIREMENTS
TIDA-00204 MEASUREMENTS
Phenomenon
Basic standard
Category 2 electric field
strength component quasi-
peak dB (µV/m)
Measured minimum margin to limit
Test
EMI
CISPR 11 / EN55011 Class
A
40 (30 to 230 MHz)
47 (230 to 1000 MHz)
Horizontal: 10.6 dB (125 MHz)
Vertical: 4.3 dB (125 Mhz)
PASS
(1)
Class A is considered when there are less than two consecutive UDP packet losses and no major drop in network utilization.
One UDP packet loss will be tolerated by the system if the following UDP packet is echoed back successfully. The test has been
conducted with a UDP error packet test program at around 5% network bandwidth.
表
表
27. IEC61800-3 and IEC61000-6-2 EMC Immunity Requirements for Second Environment and
Measured Voltage Levels and Class
REQUIREMENTS
TIDA-00204 MEASUREMENTS
Port
Phenomenon
Basic
standard
Level
Performance
(acceptance)
criterion
Level
Performance
Criterion
Test
Enclosure
ports
ESD
IEC61000-4-2
±4-kV CD or
8-kV AD, if CD
not possible
B
±6-kV CD
B
PASS
(EXCEED)
Ports for
control lines
and DC
auxiliary
supplies <60 V
EFT
IEC61000-4-4
±2-kV/5-kHz,
capacitive
clamp
B
±4 kV
B
PASS
(EXCEED)
Surge 1.2/50
µs, 8/20 µs
IEC61000-4-5
±1-kV; since
shielded cable
>20-m, direct
coupling to
shield (2
Ω
/500 A)
B
±2 kV
A
(1)
PASS
(EXCEED)
The performance (acceptance) criterion is defined as follows:
表
表
28. Performance (Acceptance) Criterion
PERFORMANCE
(ACCEPTANCE)
CRITERION
DESCRIPTION
A
The module shall continue to operate as intended. No loss of function or performance even during the test.
B
Temporary degradation of performance is accepted. After the test, the module shall continue to operate as
intended without manual intervention.
C
During the test, loss of functions accepted, but no destruction of hardware or software. After the test, the
module shall continue to operate as intended automatically, after manual restart, or power off, or power on.