Test Results
67
JAJU324B – March 2015 – Revised July 2017
翻訳版
—
最新の英語版資料
http://www-s.ti.com/sc/techlit/TIDU832
Copyright © 2015–2017, Texas Instruments Incorporated
EMI/EMC
規格準拠、産業用温度範囲のデュアルポート・ギガビット・イーサネットの
リファレンス・デザイン
5.4.2.1
Pre-Test Results With 3-m Antenna Distance
CAUTION
Due to the shorter distance (3 m instead of 10 m), the threshold for EN55011
for radiated EMI is higher by 10 dB as well. The setup is shown in
図
図
59. Automatic Pre-Test Setup for EMI With 3-m Antenna Distance to DuT
(Left: Antenna, Right: TIDA-00204 DuT and Box With Shielded Laptops)
A pre-test was done to identify the critical frequencies on each polarization. This test has been done in a
chamber with a 3-m distance to the antenna.
表
表
31. Pre-Test Equipment Setup
TYPE
NAME
Antenna
A5_VULB9168_24-14-007
Cable
A5_Cable_50-13-018
Cable
A5_Cable_50-13-019
Preamplifier
Ohm1_MTS TVV-695_50-01-059
Receiver
Ohm1_FSP7_11-05-002
Turntable
CO1000