9.5.1.5 FLAG1 Register (Address = 0x4) [reset = 0x0]
.
Return to
.
Clear on Read
Figure 9-20. FLAG1 Register
7
6
5
4
3
2
1
0
VIN_OVP_FAU
LT_FLAG
RESERVED
BAT_OCP_FAU
LT_FLAG
BAT_UVLO_FA
ULT_FLAG
TS_COLD_FLA
G
TS_COOL_FLA
G
TS_WARM_FL
AG
TS_HOT_FLAG
RC-1b0
RC-1b0
RC-1b0
RC-1b0
RC-1b0
RC-1b0
RC-1b0
RC-1b0
Table 9-14. FLAG1 Register Field Descriptions
Bit
Field
Type
Reset
Description
7
VIN_OVP_FAULT_FLAG
RC
1b0
VIN Over Voltage Fault Flag
1b0 = No overvoltage condition detected
1b1 = VIN overvoltage condition detected
6
RESERVED
RC
1b0
Reserved
5
BAT_OCP_FAULT_FLAG RC
1b0
Battery Over Current Protection Flag
1b0 = No Battery Over Current condition detected
1b1 = Battery Over Current condition detected
4
BAT_UVLO_FAULT_FLAG RC
1b0
Battery Under Voltage Flag
1b0 = Battery below BATUVLO condition detected
1b1 = No Battery below BATUVLO condition detected
3
TS_COLD_FLAG
RC
1b0
TS Cold Region Entry Flag
1b0 = TS Cold Region Entry not detected
1b1 = TS Cold Region Entry detected
2
TS_COOL_FLAG
RC
1b0
TS Cool Region Entry Flag
1b0 = TS Cool Region Entry not detected
1b1 = TS Co0l Region Entry detected
1
TS_WARM_FLAG
RC
1b0
TS Warm Region Entry Flag
1b0 = TS Warm Region Entry not detected
1b1 = TS Warm Region Entry detected
0
TS_HOT_FLAG
RC
1b0
TS Hot Region Entry Flag
1b0 = TS Hot Region Entry not detected
1b1 = TS Hot Region Entry detected
SLUSEC5 – DECEMBER 2020