89
2. First the EUT power has to be switched ON via front panel or WIN 3000
software. This way allows dual drive, as the EUT power can then be switched
OFF either from software control or from this external drive.
3. This signal is also used to drive the orange lamp of INA 3001 warning lamps.
9.7 High voltage active
Between pin 16 (Hi) and pin 2, 8, 15, 20 (low).
This function is activated for firmware revisions 2.30 and higher.
This output is to drive external warning lamps INA 3001. The HV on signal is
working together with the high voltage LED located on the front panel.
Output high (24 V): High voltage is ON
Output low (0 V): High voltage is OFF