141
Technical specifications
Parameter
Value
Max. operating voltage:
AC 250 V
DC 250 V
Max. operating current:
0.5 A
Ohmic resistamce per path:
3 Ω
Decoupling chokes 1 KHz:
20 mH nominal
Pulse:
1.2/50 and 10/700 μs pulse
Max. pulse voltage:
6.6 kV line to ground, 3 kV line to line
Accessories:
Resistor networks:
INA 172 4 x 100 Ω, 6 W
INA 175 4 x 160 Ω, 6 W
Coupling adapters:
INA 170 Sparkling gap device,
90 V trip voltage
INA 171 Capacity 0.1 μF//spark gap
device, 90 V trip voltage
INA 173 Short circuit connector