61
Note:
Burst coupling is always to HF reference ground.
8.3.8 Burst time
Touch the “burst time” button (15 in the example) to set the burst time. A red
frame is displayed around the field. The burst time may be entered using the
wheel or the keypad.
Touch the “units” button (ms in the example) to set the time unit. Time units
are
s, ms, µs
and
spikes.
8.3.9 Repetition time
Touch the “Repetition time” button (300 in the example) to set the test repeti-
tion time. A red frame is displayed around the field. The repetition time may be
entered using the wheel or the keypad.
Touch the “units” button (ms in the example) to set the time unit. Time units
are
s
and
ms
.
Note:
The repetition time must be shorter than the test duration.
8.3.10 Test duration
Touch the “Test Duration” button (120 in the example) to set the test dura-
tion time. A red frame is displayed around the field. The duration time may be
entered using the wheel or the keypad.
Touch the “units” button (s in the example) to set the time unit. Time units are
s, min, h
and
cont (continuous).
Coupling selection window