background image

 

V13 – 26.03.2019 

1

 

 

 

 

Instruction Manual 

TESA CLINOBEVEL 3 

ELECTRONIC INCLINOMETER 

 

 

05330210

TESA CLINOBEVEL 3 

± 60°,

 Cast iron, rust protected 

 

05330211

TESA CLINOBEVEL 3 

± 60°,

 Aluminium, black anodized 

 

05330212

TESA CLINOBEVEL 3 

± 10°,

 Cast iron, rust protected 

 

05330213

TESA CLINOBEVEL 3 

± 10°,

 Aluminium, black anodized 

 

05330214

TESA CLINOBEVEL 3 

High Precision

 

± 1°,

 Cast iron, rust protected 

 

 
 
 
 
 
 
 
 
 
 
 

 

This document is confidential and only to be used internally by the company that has purchased one of the inclinometers 
mentioned above. Before duplicating or transmitting it to third parties without any connection to the use of these instruments, 
an official request has to be sent to TESA. 

 

Summary of Contents for 05330210

Page 1: ... rust protected 05330213 TESA CLINOBEVEL 3 10 Aluminium black anodized 05330214 TESA CLINOBEVEL 3 High Precision 1 Cast iron rust protected This document is confidential and only to be used internally by the company that has purchased one of the inclinometers mentioned above Before duplicating or transmitting it to third parties without any connection to the use of these instruments an official re...

Page 2: ...r 13 3 4 Display brightness 14 3 5 Short description of the individual display areas 14 3 6 Mirroring the display 15 4 TECHNICAL SPECIFICATIONS 16 5 DELIVERY CONTENTS 17 5 1 System components 17 5 2 Packaging 17 6 INSTALLATION SECURITY MAINTENANCE 18 6 1 Location 18 6 2 Place of use 18 6 3 Lighting 18 6 4 Measuring surface 18 6 5 Cleanliness 18 6 6 Vibrations 18 6 7 Care of the batteries 18 7 FUNC...

Page 3: ... on or off 33 8 7 Hide disabled Functions 33 8 8 Switch wireless connection on off 34 8 9 Gravitation 34 8 10 Firmware Version 35 8 11 Reset quick calibration 35 8 12 Reset to factory settings 36 8 13 Function check 36 9 READING OUT MEASURIEMENT DATA WITH THE HYPERTERMINAL 37 10 ERROR MESSAGE 37 11 PIN DEFINITION 38 12 ACCESSORY 38 13 DECLARATION OF CONFORMITY 38 14 WARRANTY 39 ...

Page 4: ...function or deterioration of the instrument 1 3 Copyright document The content of this document has been created subject to subsequent modifications without prior notice All modification rights are reserved The German version is the reference language All other language versions are only translations 1 4 Preamble The TESA CLINOBEVEL 3 is the result of more than 70 years of experience in the concep...

Page 5: ...rement zones 1 10 60 TESA CLINOBEVEL 3 with the measuring ranges 10 and 60 is available in cast iron and aluminium The version with the measuring range 1 is only available in cast iron and its measuring bases on the left and bottom are precisely scraped The TESA CLINOBEVEL 3 allows wireless data transmission to an Android device The app can be downloaded from the Play Store Various parameters can ...

Page 6: ...cription of the constitutive elements of the TESA CLINOBEVEL 3 No Description 1 Wooden thermal protection handle 2 Keys 3 External connection 4 Measuring units 5 Battery display 6 Function indicator and infrared indicator 7 Sensor address 8 Main display 9 Cross vial 9 1 2 3 5 6 7 8 4 ...

Page 7: ...function test and establishes connections to other instruments if any had been available The instrument changes into measuring mode The settings which were used prior to switching the instrument off are reloaded The TESA CLINOBEVEL 3 features an automatic shut off mechanism In normal mode the instrument is automatically switched off 60 minutes after the last key operation This automatic shut OFF f...

Page 8: ...utomatic off function is deactivated Exception If the TESA CLINOBEVEL 3 is powered from an external power supply the automatic off function is deactivated and the instrument will remain on Function 2 To switch off press the key more than 3 seconds until the display disappears Function 3 With the key you open the menu selection Pressing the key repeatedly will move the cursor down to the desired po...

Page 9: ...e is sent to the RS 485 port Function 3 Escape function from the menu ZERO SELECT key Function 1 The key is used to changing the scale in the display increase decrease the display range This function can however be disabled in the instrument settings Function 2 The key is used to select possible adjustments such as menu selection modification of a figure in the menu HOLD key Function 1 The key ser...

Page 10: ...sposal through household waste is prohibited Batteries accumulators containing contaminants are marked with the symbol shown which clearly indicates the prohibition of disposal through household waste You can dispose of your used batteries accumulators free of charge at the collecting points of your community your TESA reseller or at each location selling batteries accumulators You thus fulfil you...

Page 11: ... reduced continuously with higher inclination values Around Zero the resolution corresponds to the unit selected In the adjustments of the instrument you can switch between linear and logarithmic scaling Using the key select the menu point Options and confirm your selection with Select now Logscale and confirm with Switch the logarithmic scaling on or off using the keys The display will show the r...

Page 12: ...45 20 10 5 2 1 30 12 for TESA CLINOBEVEL 3 High Precision 1 30 12 6 3 1 Numeric display plus vial spirit level Display ranges 60 45 20 10 5 2 1 30 12 for TESA CLINOBEVEL 3 High Precision 1 30 12 6 3 1 Numeric display plus simple vial spirit level Display ranges 60 45 20 10 5 2 1 30 12 for TESA CLINOBEVEL 3 High Precision 1 30 12 6 3 1 Numeric plus LED display Display ranges 60 45 20 10 5 2 1 30 12...

Page 13: ...ness of the colour selected the colour of the fonts and the symbols will change between black and white Using the key select the menu point Options and confirm your selection with Select now Display Settings and confirm with With the keys select the background colour and confirm the selection with the key The measuring instrument returns to the measuring mode The following background colours are a...

Page 14: ...supply and Brightness Battery for the adjustment in battery operation Confirm this selection with With the keys you can adjust the brightness required The display will show the power consumption in a range from 10 to 100 of the maximum brightness Only steps of 10 are possible Confirm the adjustment with the key With the key the default value of 50 will be recalled The measuring instrument returns ...

Page 15: ...ows the serial number of the instrument Battery voltage 26 Display of the current battery voltage example 2 6 V The lowest possible voltage is 1 7 Volt After a further voltage drop a blinking battery symbol will appear The batteries must then be exchanged immediately Measuring unit Display of the measuring unit in use There are 10 basic units available whereas for each setting various options can ...

Page 16: ... output USB RS 485 asynchr 7 DataBits 2 Stopbits No Parity 9600 Baud Batteries Size LR14 Type C Lifetime 2 x 1 5 V NiMH NiCd NiZn 25 hours Dimensions weight Housing Net weight Cast iron rust protected Aluminium black anodized 150 x 150 x 40 mm 3 45 kg 150 x 150 x 40 mm 1 5 kg Temperature range Operating temperature Storage temperature 0 to 40 C 20 to 70 C Two prismatic measuring bases Flat measuri...

Page 17: ...on 60 Infrared remote control article number 05360014 only for version 1 2 batteries LR14 Case Instruction Manual 5 2 Packaging The elements that constitute the packaging of the TESA CLINOBEVEL 3 are very important therefore you should keep them It is absolutely necessary to use the original packaging when transporting the instrument in order to avoid any unfortunate deterioration which could caus...

Page 18: ...plits or joints It is recommended to use a measuring surface that is big enough to enable smooth and easy movements of the instrument around the workpiece to be measured if the latter cannot be displaced manually 6 5 Cleanliness Make sure that the measuring surface is clean so that there is no dust condensation or metal filings 6 6 Vibrations Floors of companies are constantly at risk of vibration...

Page 19: ...BEVEL 3 have the same temperature and that the instrument is in operation for several minutes before starting a measurement Mark the precise position and particularly the direction of the TESA CLINOBEVEL 3 in order to be able to turn the instrument by 180 degrees and to put it in opposite direction at the very same spot The absolute zero will be determined from a reversal measurement two measureme...

Page 20: ...ow the current measurement Complete the measurement with the key or with the remote control After 15 seconds the measuring value will automatically be read After termination of the reversal measurement the display for the actual measurement under consideration of the ZERO OFFSET will appear on the screen The value of the Zero Offset determined by a reversal measurement corresponds to the deviation...

Page 21: ...ve base 4 decimals xxxx xx A o artillerie permille xxxx xx o permille xxx xxx DEG degrees 3 decimals xxx xx DEG degrees minutes xx xx xx DEG degrees minutes seconds xxxx xx DEG minutes seconds xxxxxx DEG seconds xxxxx x DEG seconds xxx xxx GON Gon 3 decimals 7 4 Units with relative base length The units mm REL and REL are related to a relative this means selectable base length After selecting one ...

Page 22: ...mode The function SEND can also be initiated from the PC Laptop connected by sending P as a letter via the RS 232 port 7 6 Selection of the filter under different measuring conditions FILTER A number of different predefined filters can be selected Description of the different filter types FILTER 1 No filtering no integration of the measuring values T const 0 33Sek FILTER 2 Floating average of 3 me...

Page 23: ...3 and can be re called again and again When starting the next relative measurement the REL ZERO OFFSET entered or determined the last time will be displayed The value can either be confirmed newly entered or set to zero VALUE displayed Value of the TESA CLINOBEVEL 3 ZERO OFFSET REL ZERO OFFSET Abbreviated procedure with the key Put the measuring instrument on the reference surface The display show...

Page 24: ... for the measurement will be shown With the key you can at this stage open the manual entry in order to enter a reference value defined by yourselves Set the TESA CLINOBEVEL 3 to the correct position and press the key to read the value Alternatively the measuring can also be started using the remote control During the measurement the display will graphically show the current measurement Complete t...

Page 25: ...u have to set one of these registers to an exact value e g 5 7 9 Measurement with Limits LIMITS If you intend to set off an Alarm when a defined limit is exceeded this can be realised using the function LIMITS The function LIMITS allows defining an upper and a lower limit If this set limit is exceeded respectively under run a horizontal bar in the display will start blinking A blinking bar above t...

Page 26: ... TESA CLINOBEVEL 3 with the measuring range 60 is equipped with an integrated calibration set up for a quick calibration procedure which enables the calibration without complex means On the backside of the TESA CLINOBEVEL 3 precisely manufactured and placed holes are available for installing the dowel pins as calibration aids These pins are part of the delivery and can be inserted into the holes W...

Page 27: ... determined 4 Correction of the value at 0 The dowel pins delivered are to be inserted now in such a way that the calibration at 0 can be defined To start the calibration press the key and hold the instrument still Alternatively the calibration can also be released with the remote control With the key you can at this point open the manual entry in order to enter a predefined correction value 5 Cor...

Page 28: ...es in the instrument must remain free from dust and dirt 7 11 Infrared remote control Procedure The measuring or display instrument must be started Keep one of the keys on the measuring or display instrument pressed Point the IR remote control in the direction of the measuring or display instrument Press the actuator key on the IR remote control until both red IR LEDs are lighting up The remote co...

Page 29: ...e app The app searches for TESA CLINOBEVEL 3 in the area After a short time your instrument should be visible with a green background Select the device The BT Discoverable function only needs to be switched on the very first time a connection is established Afterwards the two paired devices will automatically find each other again ...

Page 30: ...Hide disabled Functions ON OFF If this option is enabled disabled functions will not be shown Option Radio ON OFF With this option the wireless data transmission can be activated or deactivated Option Gravitation With this function the correction of the gravitation can be switched on or off and the local gravity force can be entered Option Version With this option the version of the firmware will ...

Page 31: ...bly reduced with a reduced brightness it is recommended to use in the energy safe mode a brightness of 50 default With the colour pattern the background colour can be adjusted The colour of the fonts changes according to the brightness of the background between black and white The default background colour is beige Using the key select the menu point Options and confirm your selection with Select ...

Page 32: ...e keys and confirm with the key The measuring instrument returns to the measuring mode 8 5 Function keys With the option Programmable Keys it is possible to switch the function of the keys and of the key on or off Using the key select the menu point Options and confirm your selection with Select now Programmable Keys and confirm with With the keys select the key you would like to switch on or off ...

Page 33: ...elected function on or off In the display the selected status will be shown ON means enabled OFF means disabled Confirm with the key The list of the switchable menu functions will be shown again For switching another function on or off repeat the procedure as described above In order to store the settings select Ok and confirm with the key The measuring instrument returns to the measuring mode 8 7...

Page 34: ... the equator 9 80620 m s2 at 45 degrees of latitude 9 83219 m s2 at the poles In the following table the values of gravity for some cities are listed Amsterdam 9 813 Istanbul 9 808 Paris 9 809 Athens 9 807 Havana 9 788 Rio de Janeiro 9 788 Auckland NZ 9 799 Helsinki 9 819 Rome 9 803 Bangkok 9 783 Kuwait 9 793 San Francisco 9 800 Brussels 9 811 Lisbon 9 801 Singapore 9 781 Buenos Aires 9 797 London...

Page 35: ...g instrument returns to the measuring mode 8 10 Firmware Version With this option information about the installed firmware and the configuration can be displayed Using the key select the menu point Options and confirm your selection with Select now Version and confirm with The following information will be displayed Serial number of the instrument Number of the firmware Firmware release date Instr...

Page 36: ...e 00000 Display settings Colour blue Saturation 100 Saturation Power saving mode 50 Logarithmic scaling OFF Function keys all keys enabled Switching functions on or off all keys enabled Hide disabled functions OFF Wireless connection ON if available Gravitation OFF Value 9 807 kg m s2 Using the key select the menu point Options and confirm your selection with Select now Factory Reset and confirm w...

Page 37: ...ram 2 Enter the COM port connected to the TESA CLINOBEVEL 3 3 Enter the parameters Bits per Second 9600 Data bits 7 Parity none Stopbits 2 Protocol none 4 Repeatedly pressing the key on the TESA CLINOBEVEL 3 the actual value will be transmitted in Rad Alternatively it can be called from the terminal program by sending the ASCII value P to the instrument 10 ERROR MESSAGE After the start of the inst...

Page 38: ...icle number 05360014 Cable RS484 USB to computer article number S53300166 13 DECLARATION OF CONFORMITY We thank you for your confidence in purchasing this product We hereby certify that it was inspected in our works We declare under our sole responsibility that its quality is in conformity with all technical standards and data as specified in our sales literature instruction manual leaflet general...

Page 39: ...ollowing services free repair by TESA or a TESA certified service shop or free replacement or credit note for the product subject to the claim All other services or compensation under a warranty claim are excluded The warranty shall not cover any damage resulting from incorrect incompetent or negligent use a maintenance defect or failure external influences failure to comply with service instructi...

Reviews: