Hydraulic Pump
74
S
®
-60/65 XC
™
• S
®
-60/65
HF • S
®
-60/65 TraX
™
Part No. 1288652GT
4
Ford models:
Close the valve on the LPG
tank then disconnect the hose from the tank.
Then move the fuel select switch to the LPG
position.
Perkins 404D-22 models:
Disconnect the
engine wiring harness from the fuel solenoid
at the injector pump.
Deutz D2011L03i, D436 L3i and
TD2011L04i models:
Hold the manual fuel
shutoff valve clockwise to the closed position.
1 manual fuel shutoff valve
5 Have another person crank the engine with
the starter motor for 15 seconds, wait
15 seconds, then crank the engine an
additional 15 seconds or until the pressure
reaches 320 psi / 22 bar.
6
Ford models:
Connect the LPG hose to the
LPG tank and open the valve on the tank.
Perkins 404D-22 models:
Connect the
engine wiring harness to the fuel solenoid.
Deutz D2011L03i, D436 L3i and
TD2011L04i models:
Release the manual
fuel shutoff valve.
7 Start the engine from the ground controls and
check for hydraulic leaks.
Summary of Contents for Genie S-60 HF
Page 195: ...April 2021 Service and Repair Manual 183 Electrical Schematic Deutz TD 2 2 L3 Models ...
Page 198: ...Service and Repair Manual April 2021 186 Electrical Schematic Deutz TD 2 2 L3 Engine Harness ...
Page 199: ...April 2021 Service and Repair Manual 187 Electrical Schematic Deutz D 2 9 L4 Models ...
Page 203: ...April 2021 Service and Repair Manual 191 Electrical Schematic Perkins 404F E22T Models ...
Page 206: ...Service and Repair Manual April 2021 194 Electrical Schematic Perkins 404D 22 Models ...
Page 207: ...April 2021 Service and Repair Manual 195 Electrical Schematic Ford MSG 425 EFI Models ...
Page 210: ...Service and Repair Manual April 2021 198 Electrical Schematic Generators ...
Page 217: ......