April 2021
Service and Repair Manual
Control System
Part No. 1288652GT
S
®
-60/65 XC
™
• S
®
-60/65
HF • S
®
-60/65 TraX
™
25
How to Adjust the Joystick Threshold Setting
How to Adjust the Joystick
Threshold Setting
The threshold setting of a joystick is the minimum
output at which a function proportional valve can
open and allow the function to operate.
The boom function threshold current should be
operating at near zero speed, smoothly with no
vibrations.
Note: Perform this procedure with the boom in the
stowed position.
1 Enter the Service Mode.
2 Press the
SETTINGS
button above the
display screen.
3 Select
SPEEDS
from the display screen.
4 Navigate to the desired function's Threshold
setting.
5 Select the desired setting to change and
press
OK
.
6 In the parameter adjustment screen, use the
display buttons to change the parameter.
Note that the factory default speed is
considered 100% for threshold values.
7 Scroll and press
OK
. The change is effective
immediately.
8 Switch the machine control to platform control
and start the engine from the platform
controls..
9 Using the joystick, verify that the function
engages smoothly and without sudden
movement or excessive joystick dead spots.
10 Adjust the parameter in the ground display to
achieve a smooth function threshold.
1-5 How to Enter ALC600 Software Update Mode
1-5
How to Enter ALC600 Software
Update Mode
1 Go to the Genie website
, select your
Machine Model
and select
Search
.
2 Download the software to a USB flash drive. If
zipped, extract the files to the USB flash drive.
3 With the machine off, open the GBOX (ground
box) lid and then remove the four Torx head
screws securing the Display Controller
(DISCON) door and remove the door to
expose the USB port.
4 Insert the flash drive into the USB port.
5 Set key switch to ground and pull out the red
ground ESTOP while holding buttons 1 and 4.
6 The Display Controller will go into the
bootloader mode.
7 Browse and select the desired
software. Follow the on-screen guidance to
start the update procedure.
8 When complete, turn off machine.
9 Remove USB flash drive, re-install the Display
Controller door and close the GBOX (ground
box).
10 Power up normally.
11 As the display controller starts, operator shall
verify on the start-up screen that the proper
software and revision are displayed.
12 Perform a function check.
Summary of Contents for Genie S-60 HF
Page 195: ...April 2021 Service and Repair Manual 183 Electrical Schematic Deutz TD 2 2 L3 Models ...
Page 198: ...Service and Repair Manual April 2021 186 Electrical Schematic Deutz TD 2 2 L3 Engine Harness ...
Page 199: ...April 2021 Service and Repair Manual 187 Electrical Schematic Deutz D 2 9 L4 Models ...
Page 203: ...April 2021 Service and Repair Manual 191 Electrical Schematic Perkins 404F E22T Models ...
Page 206: ...Service and Repair Manual April 2021 194 Electrical Schematic Perkins 404D 22 Models ...
Page 207: ...April 2021 Service and Repair Manual 195 Electrical Schematic Ford MSG 425 EFI Models ...
Page 210: ...Service and Repair Manual April 2021 198 Electrical Schematic Generators ...
Page 217: ......