Service and Repair Manual
April 2021
Deutz D 2.9 L4 Engine Fault Codes
158
S
®
-60/65 XC
™
• S
®
-60/65
HF • S
®
-60/65 TraX
™
Part No. 1288652GT
SPN = Suspect Parameter Number
FMI = Failure Mode Identifier
KWP = Keyword Protocol
SPN
FMI KWP
Description
4766
0
1029 Physical range check high for
exhaust gas temperature
downstream (DOC)
4766
1
1032 Physical range check low for
exhaust gas temperature
downstream (DOC)
4768
2
1036 Sensor exhaust gas temperature
upstream (DOC); plausibility
error
4768
3
1044 Sensor error exhaust gas
temperature upstream (DOC);
signal range check high
4768
4
1045 Sensor error exhaust gas
temperature upstream (DOC)
signal range check low
4769
2
1026 Sensor exhaust gas temperature
downstream (DOC); plausibility
error
4769
3
1034 Sensor error exhaust gas
temperature downstream (DOC);
signal range check high
4769
4
1035 Sensor error exhaust gas
temperature downstream (DOC);
signal range check low
523006 3
34
Controller mode switch; short
circuit to battery
523006 4
35
Controller mode switch; short
circuit to ground
523008 1
648
Manipulation control was
triggered
523008 2
649
Timeout error in Manipulation
control
523009 9
825
Pressure Relief Valve (PRV)
reached maximun allowed
opening count
523009 10 833
Pressure relief valve (PRV)
reached maximun allowed open
time
SPN
FMI KWP
Description
523212 9
171 Timeout Error of CAN-Receive-
Frame ComEngPrt; Engine
Protection
523216 9
198 Timeout Error of CAN-Receive-
Frame PrHtEnCmd; pre-heat
command, engine command
523240 9
179 Timeout CAN-message
FunModCtl; Function Mode
Control
523350 4
565 Injector cylinder-bank 1; short
circuit
523352 4
566 Injector cylinder-bank 2; short
circuit
523354 12 567 Injector powerstage output
defect
523470 2
826 Pressure Relief Valve (PRV)
forced to open; performed by
pressure increase
523470 2
827 Pressure Relief Valve (PRV)
forced to open; performed by
pressure shock
523470 7
876 Maximum rail pressure in limp
home mode exceeded (PRV)
523470 11 831 The PRV can not be opened at
this operating point with a
pressure shock
523470 11 832 Rail pressure out of tolerance
range
523470 12 828 Open Pressure Relief Valve
(PRV); shut off condition
523470 12 829 Open Pressure Relief Valve
(PRV); warning condition
523470 14 830 Pressure Relief Valve (PRV) is
open
523550 12 980 T50 start switch active for too
long
523601 13 948 Sensor supply voltage monitor
3 error (ECU)
523603 9
126 Timeout Error of CAN-Receive-
Frame AMB; Ambient
Temperature Sensor
Summary of Contents for Genie S-60 HF
Page 195: ...April 2021 Service and Repair Manual 183 Electrical Schematic Deutz TD 2 2 L3 Models ...
Page 198: ...Service and Repair Manual April 2021 186 Electrical Schematic Deutz TD 2 2 L3 Engine Harness ...
Page 199: ...April 2021 Service and Repair Manual 187 Electrical Schematic Deutz D 2 9 L4 Models ...
Page 203: ...April 2021 Service and Repair Manual 191 Electrical Schematic Perkins 404F E22T Models ...
Page 206: ...Service and Repair Manual April 2021 194 Electrical Schematic Perkins 404D 22 Models ...
Page 207: ...April 2021 Service and Repair Manual 195 Electrical Schematic Ford MSG 425 EFI Models ...
Page 210: ...Service and Repair Manual April 2021 198 Electrical Schematic Generators ...
Page 217: ......