April 2021
Service and Repair Manual
Deutz D 2.9 L4 Engine Fault Codes
Part No. 1288652GT
S
®
-60/65 XC
™
• S
®
-60/65
HF • S
®
-60/65 TraX
™
159
SPN = Suspect Parameter Number
FMI = Failure Mode Identifier
KWP = Keyword Protocol
SPN
FMI KWP
Description
523605 9
300 Timeout Error of CAN-Receive-
Frame TSC1AE; Traction
Control
523606 9
301 Timeout Error of CAN-Receive-
Frame TSC1AR; Retarder
523612 12 387 Internal software error ECU;
injection cut off
523612 12 612 Internal ECU monitoring
detection reported error
523612 12 613 Internal ECU monitoring
detection reported error
523612 12 614 Internal ECU monitoring
detection reported error
523612 12 615 Internal ECU monitoring
detection reported error
523612 12 616 Internal ECU monitoring
detection reported error
523612 12 617 Internal ECU monitoring
detection reported error
523612 12 618 Internal ECU monitoring
detection reported error
523612 12 619 Internal ECU monitoring
detection reported error
523612 12 620 Internal ECU monitoring
detection reported error
523612 12 621 Internal ECU monitoring
detection reported error
523612 12 623 Internal ECU monitoring
detection reported error
523612 12 624 Internal ECU monitoring
detection reported error
523612 12 625 Internal ECU monitoring
detection reported error
523612 12 627 Internal ECU monitoring
detection reported error
523612 12 628 Internal ECU monitoring
detection reported error
SPN
FMI KWP
Description
523612 12 637 Internal ECU monitoring
detection reported error
523612 12 1170 Internal software error ECU
523612 14 973 Softwarereset CPU SWReset_0
523612 14 974 Softwarereset CPU SWReset_1
523612 14 975 Softwarereset CPU SWReset_2
523613 0
856 Maximum positive deviation of
rail pressure exceeded
(RailMeUn0)
523613 0
857 Maximum positive deviation of
rail pressure in metering unit
exceeded (RailMeUn1)
523613 0
858 Railsystem leakage detected
(RailMeUn10)
523613 0
859 Maximum negative deviation of
rail pressure in metering unit
exceeded (RailMeUn2)
523613 0
860 Negative deviation of rail
pressure second stage
(RailMeUn22)
523613 0
862 Maximum rail pressure
exceeded (RailMeUn4)
523613 1
861 Minimum rail pressure exceeded
(RailMeUn3)
523613 2
864 Setpoint of metering unit in
overrun mode not plausible
523615 3
594 Metering unit (Fuel-System);
short circuit to battery highside
523615 3
596 Metering unit (Fuel-System);
short circuit to battery low side
523615 4
595 Metering unit (Fuel-System);
short circuit to ground high side
523615 4
597 Metering Unit (Fuel-System);
short circuit to ground low side
523615 5
592 Metering unit (Fuel-System);
open load
523615 12 593 Metering unit (Fuel-System);
powerstage over temperature
523619 2
488 Physical range check high for
exhaust gas temperature
upstrem (SCR-CAT)
523698 11 122 Shut off request from
supervisory monitoring function
Summary of Contents for Genie S-60 HF
Page 195: ...April 2021 Service and Repair Manual 183 Electrical Schematic Deutz TD 2 2 L3 Models ...
Page 198: ...Service and Repair Manual April 2021 186 Electrical Schematic Deutz TD 2 2 L3 Engine Harness ...
Page 199: ...April 2021 Service and Repair Manual 187 Electrical Schematic Deutz D 2 9 L4 Models ...
Page 203: ...April 2021 Service and Repair Manual 191 Electrical Schematic Perkins 404F E22T Models ...
Page 206: ...Service and Repair Manual April 2021 194 Electrical Schematic Perkins 404D 22 Models ...
Page 207: ...April 2021 Service and Repair Manual 195 Electrical Schematic Ford MSG 425 EFI Models ...
Page 210: ...Service and Repair Manual April 2021 198 Electrical Schematic Generators ...
Page 217: ......