April 2021
Service and Repair Manual
Control System Fault Codes
Part No. 1288652GT
S
®
-60/65 XC
™
• S
®
-60/65
HF • S
®
-60/65 TraX
™
129
ID Component ID Name Cause
Effect
Solution
26 Pri Boom
Ext Coil
11 Shorted
to
supply
voltage
TCON detected that
C7PBE circuit is
shorted to 12 V or
GND.
Boom Extend and
Retract functions will
not operate.
* With a voltmeter, measure Y26.
Proper resistance should be between
5 - 60 ohms. Replace Y26 if
resistance is outside of those values.
* Verify wiring for C7PBE (BK, TCON
J4-7) and check for open or short
circuits.
27 Pri Boom
Ret Coil
11 Shorted
to
supply
voltage
TCON detected that
C8PBR circuit is
shorted to 12 V or
GND.
Boom Extend and
Retract functions will
not operate.
* With a voltmeter, measure Y25.
Proper resistance should be between
5 - 60 ohms. Replace Y25 if
resistance is outside of those values.
* Verify wiring for C8PBR (BK/WH,
TCON J4-8) and check for open or
short circuits.
* Verify resistance between Recovery
Module pins J37-5 and J37-8 is zero
ohms.
35 Ground
Control
Button
27 Active
at
startup
Buttons were held
at system start, or
are shorted on the
ground control
panel.
The function
associated with the
stuck button will not
operate.
*Release the ground control buttons
and cycle power.
*If problem persists, open ground
control box and open the Display
Controller access door, being careful
to keep water out. Verify the ribbon
cables are properly seated and dry.
*Re-seat and/or replace ribbon cables
if necessary.
*Replace ground control overlay.
36 Jib Up Coil 11 Shorted
to
supply
voltage
PCON detected that
V43JU circuit is
shorted to 12 V or
GND.
Jip Up function will
not operate.
* With a voltmeter, measure Y68.
Proper resistance should be between
5 - 60 ohms. Replace Y68 if
resistance is outside of those values.
* Verify wiring for V43JU (BL, PCON
J12-8) and check for open or short
circuits.
37 Jib Down
Coil
11 Shorted
to
supply
voltage
PCON detected that
V44JD circuit is
shorted to 12 V or
GND.
Jib Down function will
not operate.
* With a voltmeter, measure Y69.
Proper resistance should be between
5 - 60 ohms. Replace Y69 if
resistance is outside of those values.
* Verify wiring for V44JD (BL/BK,
PCON J12-9) and check for open or
short circuits.
Summary of Contents for Genie S-60 HF
Page 195: ...April 2021 Service and Repair Manual 183 Electrical Schematic Deutz TD 2 2 L3 Models ...
Page 198: ...Service and Repair Manual April 2021 186 Electrical Schematic Deutz TD 2 2 L3 Engine Harness ...
Page 199: ...April 2021 Service and Repair Manual 187 Electrical Schematic Deutz D 2 9 L4 Models ...
Page 203: ...April 2021 Service and Repair Manual 191 Electrical Schematic Perkins 404F E22T Models ...
Page 206: ...Service and Repair Manual April 2021 194 Electrical Schematic Perkins 404D 22 Models ...
Page 207: ...April 2021 Service and Repair Manual 195 Electrical Schematic Ford MSG 425 EFI Models ...
Page 210: ...Service and Repair Manual April 2021 198 Electrical Schematic Generators ...
Page 217: ......