OLT6 and 1134 Description Installation and Turnup Guide
Page 15 of 50
Card Type
Power Draw (Watts)
Ethernet Switch Unit (ESU30)
30
Ethernet Switch Unit (ESU32)
35
Quad-port Optical Interface Unit (QOIU7)
65
8 Port Optical Interface Unit (OIU8)
135
Note: The 1134 shelf does not have a power on/off switch as it is not intended to
power down the shelf while it is in service. All cards and the fan module are ‘hot
inserted’ i.e. can be replaced with the power on. This is part of the redundancy design
and ensures continued service while replacing cards or the fan module.
Physical Specifications
Physical Specifications
Value
Comments
Weight
28lb/12.7kg
Depth
16 in/40.64cm
Width
19in/43.18cm
Height
6 in/15.24cm
Environmental Specifications
Environmental Specifications
Value
Comments
Temperature
-40°F/-40°C to +158°F/+70°C
Relative Humidity
5% to 95% noncondensing
Altitude
-220ft/-61m to +10,000ft/+3km
Fan
950CFM integrated with horizontal discharge
Airflow is left to right.
Compliance