background image

 

20 

Function buttons available in the “

Device register

” menu: 

 : save database to file 

: load database from file 

 : add new device 

 : clone entry (duplicate) 

 : edit entry 

 : delete entry 

Data stored by the device register: 

Device name

: custom name 

SIM identifier (ICCID)

: the identifier of the SIM card inserted into the device (if the SIM card is 

inserted, the software reads the ID automatically from the device and inserts the data in this field 
when you create a new device availability entry) 

Comment

: in this field you can enter custom comments related to the given device

 

Connection  type

:  you  can  configure  multiple  remote  availabilities  for  the  same  device 

(TEX-MVP,  TELLMon,  cloud,  peer-to-peer),  according  to  what  type  of  server  or  receiver  the 
device connects to. The availabilities belonging to given types of connection can be configured 
under the tabs labeled with the name of the connection type. 

 

A  green 

  icon  will  be  shown  on  the  tabs  of  connection  types  for  which  device  availabilities 

have  already  been  provided,  and  a  red 

  icon  will  be  shown  on  the  tabs  where  availabilities 

have not been configured or  the data are deficient. To make it easier for you,  the program will 
automatically  fill  in  the  data fields for  connection types for  which  the  availabilities  are available 
(e.g. if the device is connected via USB, the program knows the availability of the cloud server, 
and the necessary device identifier will be read automatically from the device via USB). 

Server/receiver address

: the IP address or domain name of the server/receiver 

Device IP address

: the static IP address of the device (in case of private APN) 

Port

: the communication port number of the server/receiver 

Server password

: (for TEX-MVP protocol only) the 20 hexadecimal-character server password 

(5x4 characters separated by hyphen) 

Device ID

: the device identifier. The format of the device identifier is: 

for  cloud  usage  and  the  TELLMon  protocol: 

FF:FF:FF:FF:FF:FF

  (6x2  hexadecimal 

characters,  unique,  burned-in  during  production  and  thereby  unchangeable  device 
identifier).  The  device  ID  (used  for  cloud  connection  and  the  TELLMon  protocol)  of  the 
connected device 

is shown in the “

Status monitoring

” menu / “

Device ID

” field. 

for the TEX-MVP protocol: 

FFF

 (3 hexadecimal characters) 

Summary of Contents for Pager4 3GA.IN4.R2

Page 1: ...Document version 5 00 10 08 2018 Product models Pager4 2G IN4 R2 Pager4 2G IN6 R1 Pager4 3G IN4 R2 Pager4 3G IN6 R1 Pager4 3GA IN4 R2 Pager4 3GA IN6 R1 Pager4 PRO 2G IN4 R2 Pager4 PRO 2G IN6 R1 Pager...

Page 2: ...ting to devices via peer to peer connection 14 4 2 4 Remote connecting to devices which are using the TEX MVP protocol 15 4 2 5 Remote connecting to devices which are using the TELLMon protocol 16 5 H...

Page 3: ...protocol up to 2 phone numbers Up to 10 notification templates can be created and assigned to events in order to configure the priorities of reporting channels used for reporting to CMS Configurable C...

Page 4: ...nd because this may damage the device 2 1 Under Voltage Lock Out UVLO function The product is provided with built in automatic power disconnection Under Voltage Lock Out function Depending on the prod...

Page 5: ...e the input choose the NC normally closed option at the given input s settings In this case the input becomes activated when shorting between the given input IN1 IN4 IN6 and the V terminal is removed...

Page 6: ...ctivated on the SIM card installed into the device should be chosen according to which services of the device you wish to use Basically for communication with receivers and servers it requires a SIM c...

Page 7: ...ose to electric motors high voltage etc Do not mount the unit in wet places or places with high degree of humidity 2 10 Putting into operation Disable voicemail and notification in SMS about missed ca...

Page 8: ...of events available in the device input events and service events An input event is generated when an input is activated but only if the device is armed or the given input is configured as a 24h zone...

Page 9: ...xt sensitive help by dragging the mouse pointer above it You can pin the help window thus making it always visible by clicking on the thumbtack icon in the top right corner of the window If you click...

Page 10: ...not been locked Click on the Connect button If the wrong password is entered the software connects to the device but the same functions will be available as when connecting without a password To try a...

Page 11: ...over the Internet Admin password the security password of the device default superadmin password 1234 Server address the IP address of the cloud server default 54 75 242 103 Port communication port n...

Page 12: ...to the server it will send the following reply Connected to IP address port number ID device identifier Using the PWD parameter is optional according to the following PWD the device password can be s...

Page 13: ...the commands mentioned above APN internet PWD 1234 APN net guest guest PWD 1234 CONNECT 54 75 242 103 2020 PWD 1234 Wait for the device s reply After it has confirmed that it has connected to the clou...

Page 14: ...ager4 programming software will be established directly peer to peer The System logs option of the programming software cannot be used in case of remote connection over the Internet Admin password the...

Page 15: ...t 3333 Server password the 20 hexadecimal character password of the TEX server 5x4 characters separated by hyphen Device ID the TEX identifier of the Pager4 to which you wish to connect to The format...

Page 16: ...rd o Super administrator permission full access to all settings Default password 1234 o Administrator permission full access to all settings except device identification settings o Connecting remotely...

Page 17: ...model i e a Pager4 device has to be connected in order to show the specific settings options of that device model However using the Offline device selector it is possible to view the settings options...

Page 18: ...button for Actual password enter the superadmin password Available options Change Admin password The administrator level password can be changed after clicking on this button Change Superadmin passwo...

Page 19: ...forgotten the device passwords and the device is locked only the manufacturer can restore the factory default settings in the service center 5 1 3 Device register The device register serves for storin...

Page 20: ...d icon will be shown on the tabs where availabilities have not been configured or the data are deficient To make it easier for you the program will automatically fill in the data fields for connection...

Page 21: ...gs are read Overwriting the device settings If you want to completely overwrite the settings you can import and write from a saved file To create a settings file configure the desired settings in the...

Page 22: ...a change is made For this click on the Write button SIM PIN code if you wish to use PIN code management enter in this section the PIN code of the SIM card installed into the device Otherwise disable...

Page 23: ...is control mode if you wish to arm and disarm the device by dry contact impulses e g pushbutton or monostable relay output using up one input This control mode uses input IN4 for the IN4 R2 model or i...

Page 24: ...t for which the Auto shutdown option is enabled if the arming disarming settings are configured to Always armed Periodic test report Interval of sending 1 to 168h the interval of periodic test report...

Page 25: ...es the system time from the GSM network and if this fails it will use the NTP servers If synchronization from the NTP servers also fails it will synchronize the date and time using the timestamp recei...

Page 26: ...ich you can generate by clicking on the QR code button Available options Read the settings from the device To read the settings from the device click on the Read button This will read all settings in...

Page 27: ...n on when the given event occurs Name the name of mobile device s user The name entered in this section will be used to identify the mobile devices upon selecting the notification channels when config...

Page 28: ...all settings in all menus Write the settings into the device After changing the settings or entering new settings in order to take effect it is necessary to write the new settings into the device by...

Page 29: ...ey is configured the SIA IP packages will be encrypted with the given key and they have to be decrypted on the receiver side using the same key The maximum length of the AES key is up to 16 characters...

Page 30: ...also possible to cancel all pending notifications for all events by entering the device password command e g 1234 using the phone s keys The superadmin and admin passwords are both accepted Incoming c...

Page 31: ...enu you can configure different templates according to which the device will send reports to CMS servers and receivers For quick and easy setup the device contains 2 built in templates named as EMPTY...

Page 32: ...ew settings in order to take effect it is necessary to write the new settings into the device by clicking on the Write button This will write the changes only but all changes made in any menu Save set...

Page 33: ...is necessary to write the new settings into the device by clicking on the Write button This will write the changes only but all changes made in any menu Save settings to file To save all device setti...

Page 34: ...hich state changes of the given input will be ignored after arming the device If the given zone is violated during the exit delay input event will not be generated The exit delay can be configured in...

Page 35: ...ngs from the device To read the settings from the device click on the Read button This will read all settings in all menus Write the settings into the device After changing the settings or entering ne...

Page 36: ...nt is indicated with 1 or E while restore is indicated with 3 or R Remote monitoring In this section you can configure the Contact ID event code for reporting to CMS and can select one of the preconfi...

Page 37: ...r of repetitions can be configured from 1 to 10 Output parameter settings this option becomes available if an output control mode is selected which has further settings In this section you can configu...

Page 38: ...the help of the checkboxes in the drop down list Message in this field you can enter a custom message of maximum 45 characters which you wish to send to the selected phone numbers mobile devices or e...

Page 39: ...ype of these events is fixed Available options Read the settings from the device To read the settings from the device click on the Read button This will read all settings in all menus Write the settin...

Page 40: ...card is not installed properly the card is damaged or the service is not available on the SIM card low GSM signal the GSM antenna is not connected insufficient supply voltage current GPRS 3G error thi...

Page 41: ...vated while the system is armed and entry delay starts Exit delay started this type of event is generated upon arming the system when exit delay starts Type the type of the event which can be new or r...

Page 42: ...n case of the IN4 R2 model Available options None the output will not be used Monostable the output will be activated for the time configured in the Duration section of the output parameter settings t...

Page 43: ...notification should be sent when the given event occurs The mobile devices should be configured in advance in the Mobile devices menu Push notification will be sent to the mobile devices enabled with...

Page 44: ...Available options Read the settings from the device To read the settings from the device click on the Read button This will read all settings in all menus Write the settings into the device After cha...

Page 45: ...L detector program with the external WAN IP address of your router and the external port and after this enter the modified URL in the Pager4 programming software Example for modification of the stream...

Page 46: ...ut automatically Available options Read the settings from the device To read the settings from the device click on the Read button This will read all settings in all menus Write the settings into the...

Page 47: ...licking on the Audio file upload button the voice message number selected in the table will be selected automatically in the dialog box as well but you can also select a different voice message number...

Page 48: ...ary Available options Read the settings from the device To read the settings from the device click on the Read button This will read all settings in all menus Write the settings into the device After...

Page 49: ...by default If you experience problems with the stability of the mobile network in the given location that is the module switches frequently between networks you can select the network you wish to use...

Page 50: ...ersion the firmware version of the device SIM identifier the identifier ICCID of the SIM card installed into the device Model the device type model Device ID the unique identifier of the device 6x2 he...

Page 51: ...ce in that case the data is downloaded automatically Arm The device can be armed by clicking on this button This option is not available if the Always armed or Bistable contact option is selected at t...

Page 52: ...power loss occurs Deactivate output 1 IN4 R2 model only Output OUT1 can be deactivated by clicking on this button Deactivate output 2 IN4 R2 model only Output OUT2 can be deactivated by clicking on t...

Page 53: ...how many events to be displayed in the list last 10 20 or all Stop monitoring Suspends listing of new events New events will not be listed until event monitoring is restarted Stop pending notificatio...

Page 54: ...H4 notifications to mobile devices 1 4 by Push notification EMAIL1 EMAIL4 notifications to addressees 1 4 by e mail Legend of notification status shown in the IP1 IP4 DTMF1 DTMF2 TEL1 TEL10 SMS TEL1 T...

Page 55: ...device MSG provides information on the SMS messages sent by the device GSMA provides information on the operation and status of the GSM modem Available options Open a new log window To open a new log...

Page 56: ...ge button Pause logging To pause logging click on the Pause button The entries accumulated while logging is paused will be added to the logs when you continue logging Continue logging To continue logg...

Page 57: ...er interface skin can be changed using the dropdown menu You can choose out of multiple appearance themes Language the user interface language can be selected from the available languages in the drop...

Page 58: ...ows the availabilities of the manufacturer the version of the programming software and the path of the data folder where the software stores the logs By double clicking on the path the data folder wil...

Page 59: ...he IN6 R1 model 1 to 2 for the IN4 R2 model S output state 0 open 1 closed Becomes open 3 beeps Becomes closed 6 beeps 3R9 Output state query R output number 1 for the IN6 R1 model 1 to 2 for the IN4...

Page 60: ...eter x with the desired value If needed use the CRQ and PWD parameter and substitute yyyy with the device password see specifications below R2 ON PWD yyyy CRQ Activating output OUT2 bistable mode IN4...

Page 61: ...using the CRQ parameter Armed the device has been armed Disarmed the device has been disarmed Arming failed the device could not be armed Disarming failed the device could not be disarmed Relay1 activ...

Page 62: ...hapter or using the reset button found on the device as follows power up the device keep the reset microswitch pressed for at least 8 seconds then release The reset microswitch is placed in horizontal...

Reviews: