Quick Instructions
Install the stand-alone BLUEbox device to the installation place.
A 12 V supply voltage is provided by a CPS22x mains adapter.
Switch on the system power and see that the “module”, “link”
and “video” -indicators on the front panel of the device are lit.
The “module” should lit green to show that hardware is
operating properly.
Connect all needed audio/data signals to their respective
connectors on the device’s rear panel.
Connect either a CVBS video signal to the BNC connector or a
S-VIDEO signal to the mini-DIN connector of the device.
Connect the Ethernet 100Base network to port “10/100Base-Tx”
in the rear panel.
Note! You can create a local WebUI connection by this
connector using an Ethernet cable (e.g. OPUS1CCC0050X
cross-connection cable).
Create management connection to the device either by over an
Ethernet network or by a Mgmt port and then set all necessary
settings in the device.
Default network addresses for the devices are are the following:
BBE: 10.9.96.10 (IP address)
BBD: 10.9.96.20 (IP address)
BBE/BBD: 255.255.255.0 (Netmask address)
Make sure that the device is not indicating any alarms or
warnings. The “module”, “link” and “video” -indicators on the
front panel should now lit green. If the “module” indicator is red,
the device in question has a module error and is giving an alarm.