R305 AT Commands
©2011 Telegesis (UK) Ltd
- 89 -
AT Command Manual (Rev 3.05)
S47
– Power Descriptor
Description
Register defining the Node‟s power
descriptor, which can be read by remote
nodes using ZigBee compliant ZDO
messaging.
Operations
R/W LOCAL
R/W REMOTE
Becomes effective
Instantly
Storage
Non-Volatile
Parameters
XXXX
The Power Descriptor as described in section
2.3.2.4 of the ZigBee specification.
Factory Default
C110
SW release
R302
S48
– Endpoint 2 Profile ID
Description
Register defining the Profile ID of the Node‟s
endpoint 2.
Operations
R/W LOCAL
R/W REMOTE
Becomes effective
Instantly
Storage
Non-Volatile
Parameters
XXXX
The 16 bit Profile ID.
Factory Default
C091
SW release
R302
S49
– Endpoint 2 Device ID
Description
Register defining the Device ID of the Node‟s
endpoint 2
Operations
R/W LOCAL
R/W REMOTE
Becomes effective
Instantly
Storage
Non-Volatile
Parameters
XXXX
The 16 bit device ID.
Factory Default
0000
SW release
R302