R305 AT Commands
©2011 Telegesis (UK) Ltd
- 55 -
AT Command Manual (Rev 3.05)
S09
– Trust Centre Link Key
Description
The link key which can be written using the
password. The default password for R3xx is
“password”.
Operations
W LOCAL
W REMOTE
Write operation
ATS09=<key>:<password>
ATREMS:<address>,09=<key>:<password>
Becomes effective
When Joining or establishing a PAN
Storage
Non Volatile
Range
From 0 to 2
128
-1
The 128-bit trust centre link key in hexadecimal
representation (32 characters).
When set to all 0s (default) a random trust centre
link key is generated when establishing a PAN.
Factory Default
00000000000000000000000000000000
SW release
R300