R305 AT Commands
©2011 Telegesis (UK) Ltd
- 73 -
AT Command Manual (Rev 3.05)
S24
– Immediate Functionality At IRQ1 (ETRX2: I/O1 ETRX3:PA1)
Description
Describes the immediate action taken on
IRQ1.
Operations
R/W LOCAL
R/W REMOTE
Becomes effective
Instantly
Storage
Non-Volatile
Parameters
XXXX
If set to 0 the functionality is disabled. Please see
section 5 for a list of available functionalities.
Factory Default
0000 (none)
SW release
R300
S25
– Immediate Functionality At IRQ2 ( (ETRX2: I/O10 ETRX3:PB0)
Description
Describes the immediate action taken on
IRQ2.
Operations
R/W LOCAL
R/W REMOTE
Becomes effective
Instantly
Storage
Non-Volatile
Parameters
XXXX
If set to 0 the functionality is disabled. Please see
section 5 for a list of available functionalities.
Factory Default
0000 (none)
SW release
R300
S26
– Immediate Functionality At IRQ3 (ETRX2: I/O11 ETRX3:PB6)
Description
Describes the immediate action taken on
IRQ3.
Operations
R/W LOCAL
R/W REMOTE
Becomes effective
Instantly
Storage
Non-Volatile
Parameters
XXXX
If set to 0 the functionality is disabled. Please see
section 5 for a list of available functionalities.
Factory Default
0000 (none)
SW release
R300