R305 AT Commands
©2011 Telegesis (UK) Ltd
- 70 -
AT Command Manual (Rev 3.05)
S1F
– A/D1 Reading (ETRX3 series ADC0)
Description
The analogue reading of A/D1 (ETRX3
series ADC0)
ETRX3: Only when bit 13 of S15 is set,
invalid otherwise
Operations
R LOCAL
R REMOTE
Becomes effective
Instantly
Storage
Instant Reading of analogue input
Parameters
XXXX
Representation
The hexadecimal reading of the analogue input in
mV (mV * 10 on the ETRX3) with respect to
ground. The return value will be undefined in case
the corresponding A/D converter has not been
enabled.
Range
ETRX2: 0000
– 04B0 (0 – 1200)
ETRX3: 0000
– 2EE0 (0 – 12000)
SW release
R300
S20
– A/D2 Reading (ETRX3 series ADC1)
Description
The analogue reading of A/D2 (ETRX3
series ADC1)
ETRX3: Only when bit 14 of S15 is set,
invalid otherwise
Operations
R LOCAL
R REMOTE
Becomes effective
Instantly
Storage
Instant Reading of analogue input
Parameters
XXXX
Representation
The hexadecimal reading of the analogue input in
mV (mV * 10 on the ETRX3) with respect to
ground. The return value will be undefined in case
the corresponding A/D converter has not been
enabled.
Range
ETRX2: 0000
– 04B0 (0 – 1200)
ETRX3: 0000
– 2EE0 (0 – 12000)
SW release
R300