Teledyne API - Model T200H/T200M Operation Manual
Introduction, Features, and Options
21
Option
Option
Number
Description/Notes
Reference
Communication Cables
For remote serial, network and Internet communication with the analyzer.
Type
Description
60A
RS-232
Shielded, straight-through DB-9F to DB-25M cable, about
1.8 m long. Used to interface with older computers or
code activated switches with DB-25 serial connectors.
Section 3.4.8
60B
RS-232
Shielded, straight-through DB-9F to DB-9F cable of about
1.8 m length.
Section 3.4.8
60C
Ethernet
Patch cable, 2 meters long, used for Internet and LAN
communications.
Section 3.4.8
60D
USB
Cable for direct connection between instrument (rear
panel USB port) and personal computer.
Section 3.4.8
USB Port
For remote connection
64A
For connection to personal computer. (Separate option only when
Option 64B,
Analog Input and USB Com Port
not elected).
Sections 3.4.8.2
and 4.11.8
Concentration Alarm Relays
Issues warning when gas concentration exceeds limits set by user.
61
Four (4) “dry contact” relays on the rear panel of the instrument. This
relay option is different from and in addition to the “Contact Closures”
that come standard on all TAPI instruments.
Section 3.4.7
RS-232 Multidrop
Enables communications between host computer and up to eight analyzers.
62
Multidrop card seated on the analyzer’s CPU card.
Each instrument in the multidrop network requres this card and a
communications cable (Option 60B).
Sections 3.4.8.3
and 4.11.9
Other Gas Options
Second gas sensor and gas conditioners
65A
Oxygen (O
2
) Sensor
3-24 and Sections
3.7.2 and 8.4
86A
Sample Gas Conditioner (Dryer/NH
3
Removal) for sample gas
stream only. Converts analyzer to dual-conditioner instrument.
(contact Sales)
87
Sample Oxygenator for proper operation of the NO
2
-to-NO catalytic
converter. Injects oxygen into sample gas that is depleted of oxygen.
(contact Sales)
Special Features
Built in features, software activated
N/A
Maintenance Mode Switch
, located inside the instrument, places
the analyzer in maintenance mode where it can continue sampling,
yet ignore calibration, diagnostic, and reset instrument commands.
This feature is of particular use for instruments connected to
Multidrop or Hessen protocol networks.
Call Technical Support for activation.
N/A
N/A
Second Language Switch
activates an alternate set of display
messages in a language other than the instrument’s default
language.
Call Technical Support for a specially programmed Disk on Module containing
the second language.
N/A
N/A
Dilution Ratio Option
allows the user to compensate for diluted
sample gas, such as in continuous emission monitoring (CEM) where
the quality of gas in a smoke stack is being tested and the sampling
method used to remove the gas from the stack dilutes the gas.
Call Technical Support for activation.
Section 4.8.2
07270D DCN7141