4250 Flow Meter
Section 2 Programming
2-8
or alkalinity of a solution) and D.O. (dissolved oxygen) in the flow
stream. You can have either pH with temperature, D.O. with
temperature, or temperature alone. The port is not dedicated to a
particular sensor, except through programming. You can change
the sensor. For example, you can change from a pH probe to a
D.O. sensor if you change the programming. Selection of one
parameter will keep the other from showing up on the menus.
Note, however, that it is possible to measure several different
stream conditions including pH and D.O. at the same time with
the YSI 600 Sonde.
The YSI 600 Sonde
The YSI 600 Sonde is a multi-purpose water quality mea-
surement device. It is intended for use in research, assessment,
and regulatory compliance. The sonde attaches to the modified
RAIN GAUGE connector on the 4250. Flow meters having only a
4-pin rain gauge connector will not support the YSI Sonde. If you
wish to upgrade your flow meter to use this system, contact the
factory. Note that you can have both the YSI 600 Sonde and the
Rain Gauge connected to the flow meter at the same time by
using a special Y-connect cable.
The YSI 600 Sonde can measure the following water qualities:
dissolved oxygen (D.O.), conductivity, temperature,
and
pH
. Conductivity measurements made by the sonde can be used
to calculate specific conductivity, salinity, and total dissolved
solids. A brief description and specifications for the YSI 600 are
printed in Section 4. You may also contact the factory or your
Teledyne Isco representative. More information on the sonde is
found in the YSI 600 Manual, shipped with each YSI 600 Sonde.
Figure 2-1 The YSI 600 Sonde
2.3.4 Step 4 - Reset Totalizer
In this step, you decide whether to reset the flow meter’s internal
flow totalizers. If the installation is permanent, you generally
won’t reset the totalizer. If you are using the flow meter as a por-
table recording unit and move it from site to site, you would gen-
erally reset the totalizer between sites.
Assembled Sonde
Conductivity (inside)
D.O. sensor
pH glass sensor
pH reference
Temperature
(Cover Removed)
Summary of Contents for 4250
Page 2: ......
Page 4: ......
Page 12: ...4250 Flow Meter Table of Contents x ...
Page 28: ...4250 Flow Meter Section 1 Introduction 1 16 ...
Page 90: ...4250 Flow Meter Section 2 Programming 2 62 ...
Page 140: ...4250 Flow Meter Section 4 Options and Accessories 4 30 ...
Page 160: ...4250 Flow Meter Appendix A Replacement Parts and Accessories A 2 ...
Page 161: ...4250 Flow Meter Appendix A Replacement Parts and Accessories A 3 ...
Page 166: ...4250 Flow Meter Appendix A Replacement Parts and Accessories A 8 ...
Page 184: ...4250 Flow Meter Appendix C General Safety Procedures C 10 ...
Page 191: ...4250 Flow Meter Appendix D Material Safety Data Sheets D 7 ...
Page 192: ...4250 Flow Meter Appendix D Material Safety Data Sheets D 8 ...
Page 196: ......
Page 198: ......
Page 200: ......
Page 202: ...Warranty ...
Page 204: ......