4250 Flow Meter
Section 4 Options and Accessories
4-5
outputs. One is an external box that converts the signals from
the flow meter to a 4-20 mA current loop. The other is an internal
circuit board containing three separate analog output circuits on
the same board.
The 4 to 20 mA current is an industrial standard current loop for
process control equipment that must respond to changing condi-
tions by varying output rates.
4.3.1 External 4-20 mA
Output Interface
The External 4-20 mA Output Interface has its own case and AC
power supply. Commercial power (120 VAC) must be available for
this device. Battery operation (12 VDC) is not feasible due to
voltage and current demands. It comes with a line cord, con-
nectors, and two interconnect cables. One cable has 6-pin M/S
connectors on both ends. This cable connects the input of the 4-20
mA Output Interface to the flow meter
Interrogator
connector.
The other cable has a three-pin plug on it that connects to the
output connector of the 4-20 mA Output Interface. This cable
ends in three pigtailed wires you connect to the equipment you
want to control with the 4-20 mA Output Interface.
Table 4-1 4-20 mA Output Interface Specifications
Power 120
VAC
1
•
8
Amp
Output Connector
3-pin male plug
Pin A: + current out
Pin B: – current out
Pin C: not used
Output Accuracy:
At 72° F (22°C)
Full Oper. Range
±0.25% of full-scale
±0.5% of full scale
Operating Temperature Range
0° to 140°F (–18° to 60°C)
Resolution 0.1%
of
full-scale
Input Connector
6-pin male M/S
Pin B: – pulse input
Pin F: + pulse input
Pins A, C, D, E: NC
Isolation
Output current optically isolated from
flow meter.
Fusing
1
•
4
Amp
internal on AC line.
Adjustments / Calibration
Factory-calibrated; when used within
range, no adjustment needed,
Maximum Distance
1,500 ft. (457.3 m) using 18 AWG wire.
Summary of Contents for 4250
Page 2: ......
Page 4: ......
Page 12: ...4250 Flow Meter Table of Contents x ...
Page 28: ...4250 Flow Meter Section 1 Introduction 1 16 ...
Page 90: ...4250 Flow Meter Section 2 Programming 2 62 ...
Page 140: ...4250 Flow Meter Section 4 Options and Accessories 4 30 ...
Page 160: ...4250 Flow Meter Appendix A Replacement Parts and Accessories A 2 ...
Page 161: ...4250 Flow Meter Appendix A Replacement Parts and Accessories A 3 ...
Page 166: ...4250 Flow Meter Appendix A Replacement Parts and Accessories A 8 ...
Page 184: ...4250 Flow Meter Appendix C General Safety Procedures C 10 ...
Page 191: ...4250 Flow Meter Appendix D Material Safety Data Sheets D 7 ...
Page 192: ...4250 Flow Meter Appendix D Material Safety Data Sheets D 8 ...
Page 196: ......
Page 198: ......
Page 200: ......
Page 202: ...Warranty ...
Page 204: ......