Section 1 Introduction
1-9
Display Type
2-line, 40 character/line alphanumeric dot matrix liquid crystal.
Power
12 to 14 VDC; 14 mA average at 12.5 VDC (printer set at 1" per hour, 1 minute level
reading interval, 5 minute velocity reading interval.)
Typical Battery Life
(Standard 4 Ampere-hour nickel-cadmium battery.) 8 to 11 days with printer set at 1"
per hour, 1 minute level reading interval, 5 minute velocity reading interval. 15 days
with printer turned
off
.
Operating Temperature
0 to 140
o
F (–18 to 60
o
C).
Storage Temperature
–40 to 140
o
F (–40 to 60
o
C).
Additional Power Required for Optional Equipment
Modem
60 mA maximum during operation; 0.1 mA maximum standby.
High-Low Alarm Relay Box
10 mA standby, typical; 190 mA - both relays operated.
Internal Printer
Chart Speeds
Off,
1
/
2
, 1, 2, or 4 inches per hour.
See Table 1-5 for longevity in days.
Ribbon
19.7 ft. (6 m) black nylon - replaceable.
Operating Speed
1.5 lines per second at 68
o
F. (20
o
C).
Character Size
0.09" high
0.07" wide (2.4mm
1.7 mm), 12 pitch.
Printer Recording Span
Chart Resolution
Display Resolution
User-selected from
1
/
4
ft. (3.6 cm) to over 30 ft. (9.1 m) with multiple over-ranges.
1
/
240
of selected recording span
0.001 ft. (0.3 mm)
Paper
4.5" wide
58 ft. (11.4 cm
17.7 m) plain white paper, replaceable.
Printer Reliability
2.5 million lines MCBF (mean cycles before failure).
Reports Printed
Program selections, interval activity reports, flow meter history.
Printer Recording Modes
Level, flow rate, rainfall, temperature, velocity, pH (or) D. O.; includes totalized flow,
sampler events,
Plotted Linear Data
3 different linear plots can be printed at the same time.
Flowlink Data Storage and Retrieval System
Memory Partitions
Maximum of 6 user-defined memory partitions for level or event storage.
Data Storage
Rate of data storage user-selected in 1, 2, 5, 10, 15, 30, 60, or 120 minute intervals.
Baud Rates
Serial connection - 300, 1200, 2400, 4800, or 9600 baud.
Serial connection with the optional internal modem - 2400 baud.
Storage
80,000 bytes, apportioned per reading as follows: flow = 4 bytes,
level = 2 bytes, sample = 4 bytes, pH or D. O. = 1 byte)
Level Data
Level readings are stored as a 16-bit number representing .1mm (0.0394 inch); effec-
tive range is 0–65279 meters.
Table 1-2 4250 Technical Specifications
Summary of Contents for 4250
Page 2: ......
Page 4: ......
Page 12: ...4250 Flow Meter Table of Contents x ...
Page 28: ...4250 Flow Meter Section 1 Introduction 1 16 ...
Page 90: ...4250 Flow Meter Section 2 Programming 2 62 ...
Page 140: ...4250 Flow Meter Section 4 Options and Accessories 4 30 ...
Page 160: ...4250 Flow Meter Appendix A Replacement Parts and Accessories A 2 ...
Page 161: ...4250 Flow Meter Appendix A Replacement Parts and Accessories A 3 ...
Page 166: ...4250 Flow Meter Appendix A Replacement Parts and Accessories A 8 ...
Page 184: ...4250 Flow Meter Appendix C General Safety Procedures C 10 ...
Page 191: ...4250 Flow Meter Appendix D Material Safety Data Sheets D 7 ...
Page 192: ...4250 Flow Meter Appendix D Material Safety Data Sheets D 8 ...
Page 196: ......
Page 198: ......
Page 200: ......
Page 202: ...Warranty ...
Page 204: ......