4250 Flow Meter
Section 1 Introduction
1-12
Table 1-5 4250 Chart Longevity
Note
Report Generator is turned off.
Chart Speed, Inch/Hour
Time to Empty Roll
4
7
1
/
4
Days
2
14
1
/
2
Days
1
29 Days
0.5
58 Days
Table 1-6 Battery Life Expectancy
Flow Meter Settings
Minimum
Default
2
Maximum
Level Reading Interval
1 Minutes
5 Minutes
Continuous
Velocity Reading Interval
5 Minutes
30 Minutes
Continuous
Printer
Off
Off
4" per Hour
Report Generator
Off
Off
Every Hour
Average Current
14 mA
11 mA
70 mA
Nickel-Cadmium
3
10.7 Days
5
13.6 Days
2.1 Days
Lead-Acid
4
17.4 Days
22.1 Days
3.4 Days
1. These values are approximations based on calculations; actual
times for your flow meter may vary substantially due to factors
of battery age, charge condition, operating temperatures, and
component differences.
“Minimum” settings are those providing the lowest average current
draw. “Maximum” settings are those requiring the highest current
draw. Your program should draw somewhere between the two. It is not
possible to calculate the current draw for every possible program com-
bination.
2. The default settings are the program entered at the factory. You can
reset the flow meter to the default program at any time by pressing the
1
and
CLEAR ENTRY
keys at the same time.
3. The nickel-cadmium battery has a capacity of 4.0 ampere-hours at
room temperature (20°C).
4. The lead-acid battery has a capacity of 6.5 ampere-hours at room tem-
perature (20°C). Both batteries are assumed to be fully-charged with
at least
95% of rated capacity
and in good condition. These calcula-
tions also assume a
5% safety factor
at the end of discharge.
Lead-acid batteries should
never
be completely discharged.
5. All fractional times are rounded down.
Summary of Contents for 4250
Page 2: ......
Page 4: ......
Page 12: ...4250 Flow Meter Table of Contents x ...
Page 28: ...4250 Flow Meter Section 1 Introduction 1 16 ...
Page 90: ...4250 Flow Meter Section 2 Programming 2 62 ...
Page 140: ...4250 Flow Meter Section 4 Options and Accessories 4 30 ...
Page 160: ...4250 Flow Meter Appendix A Replacement Parts and Accessories A 2 ...
Page 161: ...4250 Flow Meter Appendix A Replacement Parts and Accessories A 3 ...
Page 166: ...4250 Flow Meter Appendix A Replacement Parts and Accessories A 8 ...
Page 184: ...4250 Flow Meter Appendix C General Safety Procedures C 10 ...
Page 191: ...4250 Flow Meter Appendix D Material Safety Data Sheets D 7 ...
Page 192: ...4250 Flow Meter Appendix D Material Safety Data Sheets D 8 ...
Page 196: ......
Page 198: ......
Page 200: ......
Page 202: ...Warranty ...
Page 204: ......