Virtual Front Panel
ST112 SONET Transmission Test Set
4–13
Optics Setup Menu, Receiver
Figure 4–11 Optics Menu
The OPTICS Setup Menu (
w
) can only be accessed when the INPUT (
q
) is set to OPTIC.
It provides four choices for OC-1 (OC1), OC-3 (OC3), OC-12 (OC12), and OC-48 (OC48). The
OC-48 setting is only active when the ST112 SONET Transmission Test Set is used
in the Combined (Dual) Mode, with an ST2400 2.4 Gb/s SDH/SONET Test Set. (
The Combined
(Dual) Mode Operation is detailed in the Applications Chapter of this manual.
) Use the arrow keys
to navigate through the menu (Figure 4–11), and the enter key to activate the selection. The STS
CHANNEL area of the menu is used to select a valid STS Channel for analysis. The total number
of Valid STS Channels will change with the Optical Rate Selected.
Mapping Setup Menu, Receiver
Figure 4–12 Receiver Payload Mapping
Select Mapping menu (
r
) to access the ST112 SONET Transmission Test Set receiver payload
maps shown in Figure 4–12 and detailed in the Bellcore GR-253-CORE standard. Use the arrow
keys to position the reverse video cursor on one of the five maps shown. Then use the enter key to
make the selection. The available maps are listed below:
•
DS3 (DS-3 Asynchronous Payload Mapping)
•
VT1.5 BIT FLOAT (DS-1 Asynchronous Payload Mapping, Float Mode)
•
VT1.5 BYTE FLOAT (DS-1 Byte Synchronous Payload Mapping, Float Mode)
•
STS-3c (STS-3 Concatenated Payload Mapping)
•
STS-12c (STS-12 Concatenated Payload Mapping)
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com