Virtual Front Panel
ST112 SONET Transmission Test Set
4–39
STS-3c Configuration Menu, Transmitter
Figure 4–45 STS-3c Configuration Menu, Transmitter
The STS-3c CONFIGURATION (
i
), shown in Figure 4–45, is output dependent. It is only
accessible when either the OC-12 or OC-3 rate is selected with 3c payload mapping. Press CTRL
T and the q key to access the Quick Setup menu. Use this menu to configure the STS-3c payload
PATTERN, that will be transmitted, and to inject a single bit error in that pattern.
Under the STS-3c (STS3C) PATTERN heading either the 2E23 Pseudo Random Bit Sequence or
the 2E23 INV (Inverted) can be selected. Use the arrow keys and enter key to change selections.
Pressing the F4 function key will inject a single error when the SINGLE ERROR INJECT
heading is selected—as shown in this example.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com