Incoming Inspection Test
B–10
ST112 SONET Transmission Test Set
18. Using the LEFT/RIGHT cursors, select CONT and then press ENTER.
19. In the receiver’s STATUS section of the front panel, observe that the following error lights
appear.
A.
Under the PAYLOAD/DS1/DS3 heading, the red LED for BIT
may flash.
B.
Under the VT PATH heading,the red LED for BIP-2 may flash.
C.
Under the VT section of the POINTER heading, the yellow
LED for NDF remains lit.
20. Using the LEFT/RIGHT cursors, select OFF and then press ENTER.
21. Press RUN/STOP twice to clear all errors.
DS1 Quick Set-Up
This section of the procedure verifies that the DS1 is functioning properly. The quick set-up
places the unit into a default mode which selects specific settings for the unit. These default
settings are preprogrammed and therefore consistent from unit to unit. Leave everything set-up as
it was in the last section. There are sixteen steps in this section of the procedure.
1. Connect the transmitter and receiver together with a DS1 patch cord. Connect one end of the
patch cord to the DS1 connector on the receiver side of the front panel. Connect the other
end of the patch cord to one of the DS1 connectors on the transmitter side of the front panel.
2. On the front panel, press SETUP until the display shows the Quick DSX Set-Up menu.
3. Using the LEFT/RIGHT cursors, select DSX1 and then press ENTER.
4. Press RUN/STOP twice to clear all errors.
5. The transmitter and receiver sides should now be linked error-free.
6. On the transmitter side of the front panel, under the DS3/VT1.5-STS3C/12C heading, press
ERR/ALM until the display shows the Single Error menu.
7. Using the LEFT/RIGHT cursors, select DS1 and then press ENTER three times.
8. On the receiver’s STATUS section of the front panel, under the PAYLOAD/DS1/DS3
heading, observe that the red LED for BIT flashed three times. Also, in the receiver’s
section of the display, observe that the value of DS1 is three.
9. On the receiver side of the front panel, under the DS3/VT1.5-STS3C/12C heading, press
ERROR until the lefthand side of the display shows DS1 on the top line and BIT on the
bottom line.
10. On the display, observe that the value of BIT equals three.
11. Press RUN/STOP twice to clear all errors.
12. On the transmitter side of the front panel, under the DS3/VT1.5-STS3C/12C heading, press
ERR/ALM until the top line of the display shows DS1 ALARMS.
13. Using the LEFT/RIGHT cursors, select AIS and then press ENTER.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com