Applications and Use
ST112 SONET Transmission Test Set
5–9
Table 5–1 VT1.5 Locations and Channel Numbering Conventions
Group #, VT #
Bellcore TA-253
VT1.5 #
(1 x 28) format
VT1.5 #
(4 x 7) format *
STS-1 SPE
Column #s
1,1 1 1
2,31,60
2,1 2 5
3,32,61
3,1 3 9
4,33,62
4,1 4 13
5,34,63
5,1 5 17
6,35,64
6,1 6 21
7,36,65
7,1 7 25
8,37,66
1,2 8 2
9,38,67
2,2 9 6
10,39,68
3,2 10 10
11,40,69
4,2 11 14
12,41,70
5,2 12 18
13,42,71
6,2 13 22
14,43,72
7,2 14 26
15,44,73
1,3 15 3
16,45,74
2,3 16 7
17,46,75
3,3 17 11
18,47,76
4,3 18 15
19,48,77
5,3 19 19
20,49,78
6,3 20 23
21,50,79
7,3 21 27
22,51,80
1,4 22 4
23,52,81
2,4 23 8
24,53,82
3,4 24 12
25,54,83
4,4 25 16
26,55,84
5,4 26 20
27,56,85
6,4 27 24
28,57,86
7,4 28 28
29,58,87
When testing provisioning or mapping (1x28 or 4x7) avoid using channels 1, 10, 19, and 28
because they are in the same logical VT slot in both configurations, as can be seen
in Figure 5–8 and Table 5–1.