Remote Commands
7–16
ST112 SONET Transmission Test Set
date?
Date Query Command
Returns a character string indicating the internally stored date.
Example:
date?
Response:
DATE
“1996/08/30”
dsx1_code [ ami | b8zs ]
DSX-1 Code Configuration Set Command
Configures the DSX-1 code for both the input and output.
Argument:
ami = Alternate Mark Inversion (bipolar).
b8zs: = bipolar with 8 zero substitution.
Example:
dsx1_code ami
Response: NONE
dsx1_code?
DSX-1 Code Configuration Query Command
Returns a character string that indicates the DSX-1 current Code Configuration
Example:
dsx1_code?
Response:
DSX1_CODE
AMI
Note:
The DSX-1 Code can be either AMI or b8zs (see DSX-1 Code Configuration)
edit_setup [n], “[s]” Edit Setup Label Set Command
Assigns a label [s] to the saved setup [n]
Augment:
n: is the setup number from 0 to 9 in decimal.
s: is the string of
Example:
edit_setup 7, “OC-12 Test”
Response:
NONE
Note:
Up to 10 ASCII characters can be saved with each of the 10 setups.
The string must be enclosed in quotation marks.
Only upper case ASCII characters A to Z and numbers 0 to 9 can be used,
along with the following ASCII symbols: # $ % & ‘ ( ) * + - , / :
edit_setup? [n]
Edit Setup Label Query Command
Returns the current label assigned to the [n] setup saved in memory
Example:
edit_setup? [n] (n = a decimal integer between 0 and 9)
Response:
EDIT_SETUP OC-12 TEST
Note:
Up to 10 ASCII characters can be saved with each of the 10 setups.
gpib_address?
GPIB Address Query Command
Returns the current address value.
Example: gpib_address?
Response: GPIB_ADDRESS
15
Note:
This command is only used through the RS-232-C Port connection.