Remote
Commands
ST112 SONET Transmission Test Set
7–41
Receiver Overhead Query Commands
rx_aps_byte?
Receiver APS Bytes Query Command
Return the current value of the APS (Automatic Protection Switching) bytes: K1 and K2
Example:
rx_aps_byte?
Response:
RX_APS_BYTE #HFF, #H55
Note:
The codes #HFF and #H55 are the hexadecimal numeric value of the K1 and
K2 bytes, respectively.
rx_j1_trace?
Receive J1 Trace Query Command
Returns the value specified in the J1 Trace message.
Example:
rx_j1_trace?
Response:
RX_J1_TRACE
[Message]
Note:
The message can be any ASCII Text String, up to 64 Characters.
rx_oh_all?
Receive Overhead All Query Command
Returns 40 bytes: 27 are valid (TOH) Section and Line overhead bytes. 9 are valid (POH )Path Overhead
bytes. And 4 are valid (VT) Virtual Tributary overhead bytes.
Table 7–1 Byte Mnemonics
TOH Section (Sec.) and Line Overhead Bytes
POH Bytes
VT Bytes
Sec.
A1
A2
C1
J1
V1
Sec.
B1
E1
F1
B3
V2
Sec.
D1
D2
D3
C2
V3
Line
H1
H2
H3
G1
V4
Line
B2
K1
K2
F2
Line
D4
D5
D6
H4
Line
D7
D8
D9
Z3
Line
D10
D11
D12
Z4
Line
S1
Z2
E2
Z5
Example:
rx_oh_all?
Response: RX_OH_ALL 0,#HF6;1,#H28;... etc.
Note:
The first number before the comma is the NR1 byte count format, ranging from
zero to thirty-five for the TOH and POH bytes in the following order: A1, A2, C1,
J1, B1, ..., B3, ..., D1, ..., Z5, and bytes thirty-six through thirty-nine are: V1, V2,
V3, V4. The #H code after the comma is corresponding byte value in non-decimal
numeric (hexadecimal).
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com