104
Phaser 840 Color Printer
X-axis motor and drive assembly
1.
Remove the right cover.
2.
Remove the left cover. Disconnect the head-tilt spring.
3.
Disconnect the X-axis motor wiring harness at the x-axis motor.
4.
Remove the two screws securing the X-axis motor and bracket in place.
5.
Rotate the black, plastic retainer counter-clockwise.
6.
Lift up on the bottom portion of the X-axis drive yoke. Lift up on the
yoke and remove the upper portion of the yoke.
7.
Rotate the X-axis cone gear counter-clockwise to remove it from the X-
axis shaft.
For reassembly, apply a
small
amount of grease on the tip of the nose cone. Apply
a
small
amount, 3 dabs, on the threads of the X-axis shaft. Be sure to rotate the
black, plastic retainer so it ends locks the yoke in position. Perform the “X-axis
scale adjustment” on page 74.
Removing the x-axis motor and drive assembly
840-4-22
X-axis drive yoke
(remove bottom first)
Retainer
Cone
gear
X-axis
motor
Summary of Contents for Phaser 840
Page 46: ...36 Phaser 840 Color Printer ...
Page 95: ...Service Guide 85 Clearing PostScript NVRAM menu item ...
Page 96: ...86 Phaser 840 Color Printer ...
Page 121: ...Service Guide 111 Figure 1 Cabinet FRUs 7 5 6 8 1 2 4 0388 21 3 ...
Page 125: ...Service Guide 115 Figure 3 Paper path FRUs 0388 16 2 1 5 11 10 9 12 6 4 3 7 13 8 ...
Page 127: ...Service Guide 117 Figure 4 Motors and fans FRUs 0388 14 7 4 3 5 6 2 1 ...
Page 129: ...Service Guide 119 Figure 5 Circuit boards FRUs 4 3 5 2 1 9 7 6 8 10 11 13 0388 13 12 ...
Page 131: ...Service Guide 121 Figure 6 Solenoids and clutches FRUs 4 5 3 2 1 0388 23 ...
Page 137: ...Service Guide 127 Figure 9 High capacity PaperTray 0388 65a 1 2 ...
Page 142: ...132 Phaser 840 Color Printer ...
Page 154: ...144 Phaser 840 Color Printer ...