Service Manual
9-11
Checks and Adjustments
9
Paper clamp alignment
1.
Either manually or using the PC diagnostics, rotate the paper clamp
to its ready position.
2.
Inspect the paper clamp to ensure it is not bowed or bend and is
parallel with the surface of the drum
3.
If necessary, loosen the three screws securing the clamp to the clamp
side plate and adjust the clamp so has about a 3 mm (1/8 in) gap from
the surface of the drum
4.
Tighten the three screws to secure the clamp in position.
5.
Repeat the adjustment for the left end of the clamp.
6.
Rotate the paper clamp so its top edge is even with the bottom edge of
the back tension blade.
Figure 9-8 Setting the paper clamp gap
Paper clamp
Loosen
screws
9482-114
3 mm gap
Paper
clamp
Drum