6-28
Phaser 600 Color Printer
6
Troubleshooting
3.
Configure SoftPC’s PC Serial Ports. Set COM1 to the Modem Port.
Flow control does not need to be checked.
4.
In the same pull down menu, set PC Memory to Expanded
Memory of 0 MB
and an Extended Memory of 1 MB.
5.
To install the diagnostics from the diskette onto your computer: type:
A:INSTALL<return>
.
6.
Connect to the directory containing the desired version of diagnostic
software.
7.
Launch the diagnostics program by typing DIAGS. Once launched,
the program repeatedly attempts to communicate with the printer.
The link status indicator, in the bottom-right corner of the screen,
reads “NO” until this link is established; once communication is
established, it reads “ok.”
If the status does not change to “ok,” then make sure the serial cable is
properly installed and that the program is using the correct serial port
(usually this is COM1:) and the correct baud rate (19.2K baud).
Figure 6-3 Configuring SoftPC’s Serial Port