Service Manual
8-43
Field Replaceable Unit Disassembly/Assembly
8
Stripper finger assembly
1.
Turn off the printer. Leave the power cord plugged in to provide a
discharge path for static electricity.
2.
Remove the roll cover as described in the topic, “Roll cover” on
page 8-2.
3.
Loosen the retainer ring on the left end.
4.
Open the fuser.
5.
Remove the C-clip securing each end of the stripper finger assembly.
6.
Slide the assembly to the left to free the right end of the assembly, and
then side it to the right to free it from the printer frame.
Reverse these steps to reinstall the stripper finger assembly. To ease
re-installation, press the end fingers inward to the center of the assembly to
compress the fingers and spacers together and keep them from rotating on the
shaft.
Tools required
■
#1 POSIDRIV® screwdriver
Figure 8-33 Removing the stripper finger assembly
C-clip
Stripper finger
assembly
C-clip
9482-56