Using Roll Mode
Roll mode gives a display similar to a strip chart recorder for low-frequency
signals. Roll mode lets you see acquired data points without waiting for the
acquisition of a complete waveform record.
Roll mode is enabled when the trigger mode is auto and the horizontal scale is set
to 40 ms/div or slower.
Quick Tips
■
Switching to Envelope or Average acquisition mode, using digital channels,
using math waveforms, turning on a bus, or switching to Normal trigger will
disable Roll mode.
■
Roll mode is disabled when you set the horizontal scale to 20 ms per division
or faster.
■
Push
Run/Stop
to halt Roll mode.
Act on Event
Have the oscilloscope perform a defined action after a defined event has
occurred. The event can be a trigger or a certain number of acquisitions. The
action can be to:
■
Stop acquisitions
■
Save a waveform or a screen image to a file
■
■
Send a pulse out the AUX OUT port
■
Generate a remote interface SRQ
■
Send an e-mail notification
■
Display a message on the oscilloscope display
1.
Push
Test
on the front panel.
2.
Push
Application
on the lower menu.
3.
Turn the multipurpose knob to select
Act on Event
.
4.
Push
Event
on the lower menu, which will display the Event Type side
menu. Select the desired event type.
Acquire the signal
46
MDO4000C Series Oscilloscope User Manual
Preliminary
Summary of Contents for MDO4000C Series
Page 2: ...P r e l i m i n a r y...
Page 20: ...Compliance Information xvi MDO4000C Series Oscilloscope User Manual P r e l i m i n a r y...
Page 74: ...Acquire the signal 52 MDO4000C Series Oscilloscope User Manual P r e l i m i n a r y...
Page 140: ...Save and recall information 118 MDO4000C Series Oscilloscope User Manual P r e l i m i n a r y...